Chapter Overview About this Manual Safety Instructions Unit Assembly Complying EMC Gateway 0362157 Mounting and Demounting Connectors and Displays Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Page 5
LED Status Display for Gateway and SERVOLINK 4 ........... 6.2.2 LED Status Display for PROFINET IO-Device ............6.2.3 7-segment Display ....................6.2.3.1 Switch-on Messages ..................... 6.2.3.2 Status Messages ....................6.2.3.3 Error Messages ..................... Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Indicates a hazardous situation which, if not avoided, may result in prop‐ erty damage. Risk symbols Risk symbol Description General hazardous situation Risk of injury due to electric shock Risk of injury due to hot surfaces Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Risk of injury due to flying objects Destruction risk of electrostatically sensitive components Risk of property damage Illustration of General Notices Symbol Description Hint with additional, further information Tip with suggestions and useful information Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
DIN VDE 0110 as well as the national accident prevention regulations shall be considered! When installing feed-in systems adhere to all applicable regulations, special safety instructions and technical connection conditions of the local DSO. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
SIEB & MEYER devices meet the requirements of the Low-Voltage Directive 2014/35/EU. The harmonized standards of DIN EN 50178 and DIN EN 60204-1 in combination with the standards DIN EN 60947 and DIN EN 61800-5-1 are applied consequently. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Protect the device against dirt and humidity. Make sure that dust plugs are plugged on optical fiber connectors equipped with them during transport of the device. Otherwise, recommissioning is potentially not possible. ▶ Never touch electronic components. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
In conditions of high humidity (>80 %) the ambient temperature must not exceed +40 °C (+104 °F). The polyester films must not come in contact with benzyl alcohol or methylene chloride. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Prevent cable loops. Therefore, the units must only be connected to earth at the provided PE connection for the mains supply line and the racks only at the provided earth screw. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
SJ/T 11364-2014 (China RoHS 2 on the restriction of the use of hazardous substances in electrical and electronic equipment) SIEB & MEYER products labeled with the symbol above do not exceed the limits of the directive SJ/T 11364-2014 for hazardous substances. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Due diligence of the machine manufacturer A first programming carried out by SIEB & MEYER does not release the machine manufacturer from his duty to check the programmed values for correctness. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Consider the connection instructions of the line filter manufacturer to ensure suffi‐ cient filter effect. Appropriate line filters are provided on demand by SIEB & MEYER (see ). For detailed information on the used device refer to the section "Technical Data". Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Page 18
Unit Assembly Complying EMC Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
SERVOLINK 4 communication are displayed by the LEDs “STA1” and “STA2”. The module is designed to be mounted on a top hat rail. Device View Fig. 1: Perspective view of gateway 0362157 Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Gateway 0362157 Dimensions Fig. 2: Dimensions of the gateway 0362157 in mm (inch) Type Plate Meaning Explanation Device designation Indicates the device type Supply voltage Indicates the maximum voltage range Current Indicates the current consumption of the device Serial number...
IP20 Weight 280 g Connecting the Gateway Fig. 3: Gateway 0362157 connected to SPS/IPC and SIEB & MEYER drives Up to 16 drives can be connected to the gateway. 4.6.1 Software Connection to the PLC The following example shows the connection to the PLC via TwinCAT3.
Page 22
Then, the gateway will be entered in the Solution Explorer containing all available drives. Add and configure several gateways ➮ If several gateways are connected, select one gateway after the other as described above. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Page 23
➮ Repeat the naming for all gateways. Each name must be unique. ➮ Repeat the device search by click on the button “Rescan Devices”. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Page 24
Click on the button “Close Window” to close the window. ➮ Select the gateway in the “Solution Explorer” and expand the node in the tree structure. ✔ The gateway shows all available drives under API. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Page 26
Configuration?” and “Restart TwinCAT System in Run Mode?” with “OK”. ✔ The configuration and the PLC program are loaded into the PLC and started. Now, the gateway has the status “Communication established”. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Page 27
Gateway 0362157 Display actual values ➮ Then, you can select the linked input and output data. ✔ The current values are displayed in the tab “Online”. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Move the screw driver upward so that the latch releases the top hat rail. Then slew the device out of the top hat rail. Fig. 4: Mounting and demounting the gateway 0362157 Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Page 30
Mounting and Demounting Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Connectors and Displays Connectors and Displays Fig. 5: Connectors and displays on the gateway 0362157 Connector Pin Assignment 6.1.1 X1 – 24 Volts Connector 4-pole Combicon connector MSTB-2,5 (Phoenix) Name Meaning 24 V Logic voltage 18 – 28 volts Ground n.c.
Assembly of Optical Fiber Cables Every optical fiber connector requires an optical fiber cable with a male connector. The following information apply for connectors used in applications with 1 mm standard plastic optical fibers. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Flashes CRC error Send the gateway to SIEB & MEYER. SL4 interrupted or CRC error in Send the gateway to all SL4 devices SIEB & MEYER. Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
The 7-segment display on the front panel shows switch-on, status and error messages as code. The three-digit error codes are displayed as sequence. 6.2.3.1 Switch-on Messages Code Description No connection to fieldbus module during initialization of fieldbus module PROFINET IO module detected Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...
Fieldbus module: Communication error to network Check Fieldbus connection. Check the PLC software. E.19. Fieldbus module: Module runs, but communication Send the gateway to SIEB & MEYER. with internal dual-port memory cannot be established Gateway 0362157 - PROFINET IO to SERVOLINK 4 Connection...