8.3.
Alignment of the set
Alignments is done in our factory, nevertheless before starting up the set it should be verified with piping
connected.
TAKE NOTE
The pump set is delivered from factory properly aligned. Nevertheless to control the alignment of the pump set,
coupling halves must be verified with the aid of a rule of as explained bellow. This check on the external face
of the coupling should be repeated at 90º.
This should be checked on your premises through possible variations during transport.
Check that the sense of rotation of the motor coincides with the sense of rotation of the
pump.
The semi-elastic coupling should always be properly aligned. Improper alignment can
cause wear to the elastic parts of the coupling (flectors), pump's mechanical seal and
motor bearings. It may also cause vibrations and damage the shaft.
RULE
CORRECT
FAULTY
After checking the alignment and before proceeding to start up the set fit the protections
of the moving parts to guarantee the safety requisites.
DO NOT START UP WITHOUT THE PROTECTION GUARDS BEING PROPERLY FITTED
RULE
WITH SPACER
RULE
FAULTY
FAULTY
25