Troubleshooting; Additional Items - Eastwood QST-30/60 Instructions Manual

Scroll compressor
Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
CAUSE
Compressor
Air demand is greater than the capacity
runs con-
of the Compressor
stantly without
Severe air leak at fittings, line or hose
cycling off
Does not run
when switch
No Power
is turned on
Air demand is greater than the capacity
Motor appears
of the Compressor
to be running
Dirt, dust and debris buildup in motor
excessively
cooling air intake grille and/or Heat
hot
exchanger

ADDITIONAL ITEMS

#31721
Replacement Eastwood Air Filter Element
#31715
Replacement Eastwood Oil Filter
#31716
Replacement Eastwood Moisture Separator
#31718
1 Quart [0.946 liter] Eastwood Synthetic Scroll Compressor Oil
#20472
Eastwood Filter Separator Regulator System
#13600
3/4 in Professional Compressed Air Line Kit
If you have any questions about the use of this product, please contact
The Eastwood Technical Assistance Service Department: 800.343.9353 >> email: techelp@eastwood.com
PDF version of this manual is available at eastwood.com
The Eastwood Company 263 Shoemaker Road, Pottstown, PA 19464, USA 800.343.9353 eastwood.com
© Copyright 2018 Easthill Group, Inc.
CORRECTION
Reduce air demand. Do not exceed 12 SCFM @ 90 PSI.
Stop compressor use, locate leak and perform repair.
Check 220/240 VAC power source and connection to unit. If it is determined
after proper diagnostics that power is present up to the Pressure Switch, call
Eastwood Tech at: 1-800-345-1178.
Reduce air demand. Do not exceed 12 SCFM @ 90 PSI.
Use a soft brush or vacuum cleaner to remove debris from grille and or
Heat Exchanger.
8/18
Instruction item #31700Q
Rev 6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

31700