B 9, B 10, B 11 13129815007 B 45 MF, B 45-2 MF Enertech AB försäkrar under eget ansvar att ovannämnda produkter är Enertech AB erklärt in eigener Verantwortung, dass obenstehende Produkte mit folgenden Normen oder anderen normativen Dokumenten i överensstämmelse med följande standarder eller andra regelgivande und anwendbare Teile in EU-Direktiven in Übereinstimmung stehen...
01. GENERAL - The contents of this manual are to be observed by all who work for any reason on the unit and its appertaining system parts. - This manual is intended especially for authorised personnel. - This manual is to be regarded as part of the burner and shall always be available near the place of installation.
02. TECHNICAL DATA Type designation B2 Model S Dimensions ø89,5 Length of Projecting from blast tube flange, size B 130-150 Burner capacity 3,1-8,2 kg/h 37,0-97,0 kW -0,5 Burner output kW Recommended nozzle Both 60° and 80° and both types S and H can be used. Which nozzle type gives the best result depends on the shape of the combustion chamber.
03. INSTALLATION Acceptance inspection Ensure that everything is delivered and that there is no transport damage. If there is anything wrong with the delivery, please report it to the supplier. Any transport damage should be reported to the forwarding company. Preparations for installation Ensure that the size and capacity range of the burner are suitable for the boiler.
05. MAINTENANCE Suspension of burner During service the burner can be hung up on the screw in the burner flange. For this there is a hole on the right side of the burner.The blast tube, shrouded disc, nozzle and electrodes are then easily accessible. Removing the blast tube 1.
05. MAINTENANCE Cleaning the fan wheel The outer fan housing half is kept firm by 5 screws. Trimming If the size of the nozzle is changed, it is suitable to first set the nozzle assembly and air according to the recommendations in section Basic settings. For the individual boiler installation, adjustments can then always be made to optimise economy, operational reliability and environmental effects.
05. MAINTENANCE Service position electric package Loosen the hexagon nut from the stud bolt. Pull the electric package backwards and rotate it ca. 90° clockwise. When required the electric package can be suspended in the cables. Pump filter When changing pump filter, see chapter 06. 171 755 19 05-01...
06. INSTRUCTIONS PUMP TYPE BFP 41L3 Technical data Viscosity range: 1,3-12,0 mm Pressure range: 7-15 bar Oil temperature: -10 to+70°C Components 1. Nozzle connection G 1/8" 2. Pressure gauge connection G 1/8" 3. Pressure control 4 mm Allen key 4. Cartridge filter 5.
06. INSTRUCTIONS PUMP TYPE BFP 41L3 BFP 41L3 operating principle When the pump is started, oil is drawn from the suction port (S) through the filter (H) to the suction port (C) of the gear-set. The oil then moves to the pressure side of the gearwheel and is thus press- urised.
06. INSTRUCTIONS PUMP TYPE BFP 41L3 Suction line tables One-pipe system One-pipe system Height Pipe diameter Height Pipe diameter ø4 mm ø5 mm ø6 mm ø4 mm ø5 mm ø6 mm With an underlying tank a one-pipe system is not recommended Two-pipe system Two-pipe system Height...
07. OIL FILTER BENTONE We recommend the use of a fine filter in front of the oil burner. For certain markets this is delivered enclosed in the carton. Specification Oil filter for light oil with disposable filter cartridge Connection: 1/4" Filter grade: 20 µm Water repellent Filter area: 0.17 m...
09. ELECTRICAL EQUIPMENT LOA24... List of components Oil burner control Photoresistor Twin thermostat Main switch Fuse, max. 10A Ignition transformer Alarm lamp Solenoid valve Signal lamp (optional) Plug-in contact, burner M1 Burner motor Plug-in contact, boiler Time meter (optional) Mains connection and fuses in accor-dance with local regulations. Function 1.
10. FAULT LOCATION Burner fails to start Possible causes Situation Remedies Motor runs Flame instability Check nozzle to burner head dimension and Burner pre-purges Incorrect head settings electrode position Check oil pressure Low oil pressure Adjust air damper Excess air Flame occurs Burner locks out Photocell not seeing light...
Page 21
OIL BURNERS MAINTENANCE INSTRUCTIONS General information If the burner starts but does not ignite Keep the boiler room clean. Ensure that the boiler Make an attempt to start the burner. room has permanent fresh air intake. Switch off before Never make close repeated start attempts. dismantling the oil burner.
Need help?
Do you have a question about the Bentone B2S Classic and is the answer not in the manual?