8. Open the four screws from the bottom of the light head and pull the bottom plate assembly out of the
light head.
9. Disconnect the heater cable from the main circuit board. This applies only for light heads with heater
option (CCV).
10. Open the four screws holding the main circuit board on the bottom plate assembly. Replace the old
circuit board with the new circuit board and re-attach the heater cable.
11. Push the bottom place assembly back to the light head and attach the bottom screws.