Dc Input (Dc Versions); Dc Output (Dc Versions); Alarm Relay Output; Rs485 Input (Not Available With L864-Mx-Ga) - OBELUX MI Series Manual

Medium-intensity aviation obstruction light
Table of Contents

Advertisement

5.2.3

DC input (DC versions)

Mark
Description
+
Positive
-
Negative
GND
Ground
Tighten the connector screws using flat-head (straight) screwdriver.
Conductor cross-section
5.2.4

DC output (DC versions)

Mark
Description
+
Positive
-
Negative
GND
Ground
This terminal is used to distribute power from the light head to the next. Tighten the connector screws using
flat-head (straight) screwdriver.
Conductor cross-section
5.2.5

Alarm Relay Output

Mark
Description
NO
Normally Open
COM
Common
NC
Normally Connected
Unused alarm relay connectors can be left floating i.e. no wiring there is required. Push-in spring
Conductor cross-section
5.2.6

RS485 input (not available with L864-MX-GA)

Mark
Description
Information
D+
Data +
RS485 non-inverting pin
D-
Data -
RS485 inverting pin
SH
Shield
Shield
The RS-485 network (bus) input. Push-in spring
Conductor cross-section
© Obelux Oy 2017
Information
Power supply input positive
Power supply input negative
Protective earth
0.2mm² - 2.5mm²
Information
Power supply output positive
Power supply output negative
Protective earth
0.2mm² - 2.5mm²
Information
In alarm, connected with COM
Common relay contact
During normal operations, connected with COM
0.2mm² - 2.5mm²
connection.
0.2mm² - 2.5mm²
Technical information in this document is subject to change without notice.
MI SERIES – Manual (v1.7)
Obelux Oy, Kutomotie 6 B, 00380 Helsinki FINLAND
connection.
Page: 12(28)