WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.

LP Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the "closed" position
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line

GAS CONVERSIONS

2. Remove grates.
3. Lift the cooktop by both front corners until the side support
4. Locate the gas pressure regulator.
5. With a flat-blade screwdriver, remove the brass cap and flip
6. Reinstall the cap and tighten with the flat-blade screwdriver.
B
C
rods snap into position.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
the brass cap over so that "LP" is visible.
NAT
A. Brass cap
LP
A. Cap
A
A
A