Installation and Connection
NOTE!
Make sure the CFW-11M inverter has the 2.0x software version or above. For more details, refer to
the "CFW-11M user manual" and the "CFW-11 programming manual".
The examples of
inputs are set to "Without External Rectifier Fault" (P0832 = 6) and "Without External Rectifier Overtemperature"
(P0833 = 4) respectively. On both examples, the CFW-11M will show F414 ("External Rectifier Fault") if DIM1
input (and therefore the RL1 output relay - "UCD1_OK / UDC2_OK" - of the CIR11) opens when the DC
bus voltage is higher than the undervoltage level and the CFW-11M PWM is enabled; or it will display F412
("External Rectifier Overtemperature") if DIM2 input (and therefore the output relay RL3 - "Without Temperature
Fault" - of CIR11) opens.
Figure 3.24 on page 3-22
(P0832 = 5) and "Without External Rectifier Overtemperature Fault" (P0833 = 4), respectively. In this case,
the CFW-11M will display A415 ("External Rectifier High Temperature" alarm) if the DIM1 (and therefore the
RL2 relay output - "Without Temperature Alarm" - of CIR11) opens, and it will display F412 ("External Rectifier
3
Overtemperature") if the DIM2 input (and therefore the RL3 relay output - "Without Temperature Fault" - of
CIR11) opens.
3-22 | UR11
Figure 3.22 on page 3-21
shows DIM1 and DIM2 digital inputs set to "Without External Rectifier Alarm"
UR11
XC2
NA1
1
C1
2
NF1
3
NA2
4
CIR11
C2
5
6
NF2
7
NA3
8
C3
9
NF3
J1
* NO - normally open contact.
C - common.
NC - normally closed contact.
Figure 3.24 - Application example with active high signal at the DIs of the CFW-11M
and
Figure 3.23 on page 3-21
UC11 (CFW11M)
XC1
4
5
XC2
4
5
XC3
4
5
PE
PE
show that the DIM1 and DIM2 digital
IPS1
DIM1
(P0832 = 5)
COM
DIM2
(P0833 = 4)
COM
GND_+24 V
+24 V

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ur111140t4szUr110893t5szUr110811t6sz

Table of Contents