Option No. : 0AXXXX-1XXXXX-2XXXXX-3XXXXX
Option
SEG1
Explanation
PAGE
Indication Details Indication
Indication
and Details
0
Option
SEG7
Explanation
PAGE
Indication Details
Indication
and Details
1
• You can set the Main address(SEG6) 0~3 range and if you set other numbers, " communication error"will
occur.
CAUTION
• If you set the SEG 3 as 0, the indoor unit will maintain the previous MAIN ADDRESS even if you input the
option value of SEG6.
• If you set the SEG 9 as 0, the indoor unit will maintain previous RMC ADDRESS even if you input the option
value of SEG11~12.
Example) If you want to set as "MAIN : 3, CHANNEL : 1, RMC : B",
SEG1
0
SEG7
1
assign option codes except SEG 1, 7 which are page options.
SEG2
MODE
Setting Main address
Details
Indication
0
A
1
SEG8
Setting RMC address
Indication
RESERVED
0
1
SEG2
SEG3
A
1
SEG8
SEG9
-
1
SEG3
SEG4
Details
No Main address
RESERVED
Main address
setting mode
SEG9
SEG10
Details
No RMC address
RESERVED
RMC address
setting mode
SEG4
-
SEG10
-
SEG5
SEG6
The unit digit of an
indoor unit
Indication
RESERVED
0~3
SEG11
SEG12
Group channel(*16)
Group address
Indication
Details
Indication
RMC1
0~2
RMC2
SEG5
SEG6
-
3
SEG11
SEG12
1
B
Details
A single
digit
Details
0~F
49