PROBLEM
The indicators on the
digital display flashes.
Operation ranges
The table below indicates the temperature and humidity ranges the air
conditioner can be operated within. Refer to the table for efficient use.
Indoor
MODE
temperature
18°C to 32°C
Cooling
(-0.4 °F to 114.8 °F)
(64°F to 90°F)
18°C to 32°C
Drying
(-0.4 °F to 114.8 °F)
(64°F to 90°F)
30°C(86°F) or
Heating
less
• Be sure to install the unit under circumstances within the allowable range of
temperature.(Extended operation range down to -25°C/-13°F in heating)
CAUTION
• Press the Power button on the remote control
to turn the unit off and switch the circuit
breaker off. Then, switch it on again.
Outdoor
Outdoor temperature
temperature
(AC030/036JXSCCH/AA)
-20 °C to 46 °C
-18 °C to 46 °C
(-4 °F to 114.8 °F)
-18 °C to 46 °C
-20 °C to 46 °C
(-4 °F to 114.8 °F)
-20 °C to 24 °C
-25 °C to 24 °C
(-4 °F to 75 °F)
(-13 °F to 75 °F)
SOLUTION
Indoor
IF OUT OF CONDITIONS
humidity
Condensation may occur on the
80% or
indoor unit with risk to have either
less
water blow off or drops on the floor.
Internal protection triggers and the
-
air conditioner will stop.
Internal protection triggers and the
-
air conditioner will stop.