Installation
4.2.2

Electrical connection of motor

4.2.2.1

EMC-compliant installation

NOTICE!
Signal interference may be caused if the connection cables are too long.
Do not exceed a cable length of 3 m.
Observe the EMC protective measures described here.
EMC filter
Each electronics and motor supply cable must be installed directly at the unit with two
windings through a suitable ferrite sleeve (e.g. Würth Elektronik No.: 74270090).
4.2.2.2

EMC suppressor circuit

Suppressor circuit 1
Fig. 7:
If a ceramic capacitor (C1) is used in the PWM
signal source with a low internal resistance.
To update the firmware using the Motion Manager software, remove capacitor C2.
Suppressor circuit 2
Fig. 8:
2nd edition, 31-03-2020
C2
220 nF
EMC suppressor circuit with ceramic capacitors
EMC suppressor circuit with suppressor diodes
U
p
U
mot
GND
C1
220 nF
U
nsoll
DIR
FG
operating mode: To avoid faults, use a
nsoll
U
p
D1
U
mot
D2
GND
0 – 10 V DC
U
nsoll
DIR
FG
7000.05061, 2nd edition,
18