Main Features; Equipment Classification; Certifications - Ce Marking; Construction Features - A2B Accorroni HUB RADIATOR MINI 6.0 Technical Information

Patented high efficiency thermodynamic boiler with heat pump with direct exchange refrigerant / water to produce domestic hot water and heating for small utilities
Table of Contents

Advertisement

1.MAIN FEATURES

1.1 CLASSIFICATION OF THE APPLIANCES
The fundamental elements that make up the system
MINI HUB RADIATOR are:
1) External motion-evaporator with electronic control
defined as: "Mono block air heat pump
split water ", fed by cooling fluid
R410A with 7.0 kW ON - OFF compressor.
2) Internal unit defined as accumulator radiator
high performance closed circuit that holds
completely separated the technical water from the
water
sanitary and is realized through 2 accumulations
sequential octagonal section, inside the
which all copper exchangers are positioned.

1.2 CERTIFICATIONS - CE MARKING

The patented MINI HUB RADIATOR system is
compliant with directives 97/23 / EC and 98/37 / EEC.
They also comply with the provisions of the
following the normes: 73/23 / CEE, 89/336 / CEE,
as amended by Directive 93/68 / EEC
The internal unit of the MINI HUB RADIATOR system
has been designed to be installed only and
exclusively inside the buildings or on special purpose
external niche thermally insulated and protected by
the
atmospheric agents, if not respected
this indication invalidates any type of warranty
warranty.
1.3 CONSTRUCTION CHARACTERISTICS
All cars are equipped with a microprocessor for
control and adjustments of operation and safety of
the units.
The products of the HUB RADIATOR MINI series
thanks to the patented direct exchange capacitors
are able to achieve high standards of energy
efficiency and SCOP.
Other construction features:
- the covering unit of the outdoor unit is made for all
sheet metal models pre-painted with epoxy powder.
The room compressor is completely isolated from the
air / refrigerant exchanger compartment; it allows to
better protect the electro mechanical components;
- the compressor is of the high rotary type efficiency,
working with R 410A refrigerant mounted on elastic
anti-vibration mounts, operated from single-phase
electric motor for all models;
- the air / refrigerant gas exchanger it is made with
copper pipes and aluminium fins blocked by
mechanical expansion of the tubes, with high heat
exchange surface;
- the fan group consists of a fan helical driven directly
by engine single phase asynchronous with thermal
protection internal. The fan is equipped with a grid
accident prevention protection;
- the rapid exchanger DHW, is made in copper
directly immersed in technical water of the indoor unit
with the FIRST IN - FIRST method OUT, so as to
eliminate the problem of legionella.
- the refrigeration circuit and the connections
between the individual components are made of
specific copper for refrigeration. They are part of the
refrigeration circuit the rolling member, the reversing
valve cycle the liquid separator;
- the electric command and control panel is directly
positioned within the covering cabinet, above the
vessel of expansion.
- the microprocessor control system with keyboard is
located on the control panel accessible directly on
the part front of the cover cabinet, and can be
remoted using the appropriate panel command and
remote control, available as an accessory, to be
installed on the wall or collection.
- the indoor unit is supplied complete with all the
special internal copper exchangers, auxiliary back up
and backup support emergency, Freon attacks, DHW
attacks, air-operated jolly valve, safety valve, filling
tap, pressure gauge, valve diverter to give priority to
healthcare, flow switch, electronic circulator, vessel of
expansion, temperature probes.
1.4 CONTENT OF THE PACKAGING
The appliance is shipped on a wooden pallet, with
protections in extruded and wrapped polystyrene
foam in a layer of plastic fabric with air bubbles.
The identification data of the appliance are shown
both on the label on the packaging and on the data
plate applied to the inside of the cover cabinet.
Do not remove the license plate for any reason
technical data, since the references contained therein
are necessary for any interventions of
maintenance.
Inside the package there is also an envelope
containing this manual and the certificate of
guarantee, which must be delivered to owner of the
appliance to keep them carefully for any future use or
for consultation.
6

Advertisement

Table of Contents
loading