Installation Of External Unit; General Indications - A2B Accorroni HUB RADIATOR MINI 6.0 Technical Information

Patented high efficiency thermodynamic boiler with heat pump with direct exchange refrigerant / water to produce domestic hot water and heating for small utilities
Table of Contents

Advertisement

3. OUTDOOR UNIT INSTALLATION

3.1 GENERAL INDICATIONS

In choosing the installation position
accurately respect the following indications:
- Make sure that the difference between INTERNAL
UNITS
and the OUTDOOR UNIT is not greater than 5.0 m.
- The appliance must be installed so
that the influences of adjacent structures and / or i
effects of particular climatic conditions (snow,
wind etc ...), do not compromise the functioning
of the product and / or the safety of people e
of assets.
- Make sure the space in the back
unit is greater than 30 cm. The part
front must have more than 60 cm. of space.
- Make sure there are no obstacles to the
free circulation of air through the
heat exchangers: A) do not arrange plants or
animals directly behind the fluss air;
B) avoid installation in the corners where it is used
the depositing of dust, leaves and whatever
can reduce the efficiency of the exchangers
obstructing the passage of air (Fig 5).
- Avoid installation in tight and small spaces
get away because they could be favored
acoustic reverberations. Inquire about the
any limits on expected noise emissions
for the area of the municipal territory in which
it is install the appliance. In case of doubt it
is it is advisable to consult a acoustic
technician, qualified for an evaluation
of the impact, to prevent disputes from
third party.
- Prevent the air expelled by the fans penetrate
through adjacent doors and / or windows,
causing disturbance to people.
- Install the outdoor unit on a rigid base equipped
with special anti-vibration pads to avoid the increase
of vibrations and noise, so as not to disturb the
neighbours (Fig.6).
- Position the air exhaust so that the flow is not
hindered in any way. In In case of strong wind,
make sure the fan functions correctly, positioning
the unit longitudinally, along a wall or using a shield.
- If the appliance must be suspended on one
external wall, the support must respect the
Technical specifications. The wall where the unit
should be installed, must be brick or material of
similar consistency, otherwise it must be reinforced.
Support brackets must be stable, durable and with
adequate degree of protection against corrosion.
WARNING! Make sure of the capacity
carrier of the part on which the
shelves and wall anchoring system
itself, depending on the weight of the appliance
to install.
- Do not install the appliance near sources
of heat and / or areas with fire hazards.
- Installation in highly atmospheric areas corrosive is
not
allowed;
Fig. 5
conditions such as near the sea, it is mandatory to
provide for a duration of lower life of the product and
in any case one more frequent and accurate
maintenance.
- In the external unit, from which it is deleted
condensation water, provide a special one
drainage and / or channelling of the same, in
so as to avoid dangerous situations
due for example to ice formation
on transit areas.
10
in
condition
particular
Fig. 6
climatic