Technical Data Table Mini Hub Radiator; Acs Hub Radiator Mini 7.0 Sampling Table - A2B Accorroni HUB RADIATOR MINI 6.0 Technical Information

Patented high efficiency thermodynamic boiler with heat pump with direct exchange refrigerant / water to produce domestic hot water and heating for small utilities
Table of Contents

Advertisement

4.4 Technical data table HUB RADIATOR MINI 6.0 - 8.0 - 11.0 - 16.0
DESCRIPTION
Thermal power (1)
Power consumption (1)
C.O.P. (1)
Thermal power (2
Power consumption (2)
C.O.P. (2)
S.C.O.P. (3)
Seasonal heating efficiency (ηs)
Energy efficiency (4)
Defrosting method
Type of refrigerant
Technical water temperature min/max
Quantity of refrigerant (pre-filled)
Min distance between outdoor and indoor unit
Max distance between outdoor and indoor unit without recharging
Max distance between outdoor and indoor unit with charging
Max height difference between outdoor and indoor unit
Refrigerant gas line connection
Fluid coolant line connection
External temperature operating limits
HR MINI accumulation water content
Max electronic inverter circulator flow rate
Max inverter electronic circulator head
Electronic absorption of the inverter electronic circulator
Expansion vessel volume
Preload expansion vessel
Safety valve calibration
Back up electrical resistance
Power supply
PERFORMANCE IN HEAT PUMP - DHW
Withdrawal profile (EN 16147)
Integrated storage tank for DHW production
Power absorbed in stand-by
ERP DATA
External unit sound power
Internal unit sound power (1Z / 2Z)
Seasonal yield (average climate, HT)
Seasonal yield (average climate, LT)
Hydraulic connections for cold water inlet and DHW outlet
System hydraulic flow and return connections
Heat loss internal unit accumulation
Internal weight of transport / operating unit
Outdoor unit weight
(1) Heating: outdoor air temperature 7 ° C db - 6 ° C wb .; water inlet / outlet temperature 30/35 ° C
(2) Heating: outdoor air temperature 7 ° C db. - 6 ° C wb.; water inlet / outlet temperature 40/45 ° C
(3) Heating: average weather conditions; T.biv = -7 ° C; water inlet / outlet temperature 30/35 ° C
(4) Water 35 ° C / 55 ° C
4.5 Sampling table DHW HUB RADIATOR MINI 6.0 - 8.0 - 11.0 - 16.0
DESCRIPTION
DHW withdrawal at 40 ° C - accumulation at 55 ° C - inlet water at 10 ° C
DHW withdrawal at 40 ° C - accumulation at 55 ° C - inlet water at 15 ° C
Recovery time heat pump from 38 ° C to 55 ° C - External temperature 7 ° C *
Recovery time heat pump + resistance from 38 ° C to 58 ° C - External temperature 7 ° C *
Water withdrawal at 40 ° C with accumulation at 62 ° C with inlet water at 10 ° C
Water withdrawal at 40 ° C with accumulation at 62 ° C with water entering at 15 ° C
Recovery time heat pump + resistance from 38 ° C to 62 ° C - External temperature 7 ° C *
Recovery time from 10 ° C to 55 ° C - External temperature 7 ° C *
* Data calculated with heating system switched off
** Continuous domestic hot water supply on one user from 7 liters per minute (inlet water 10 ° C - outlet 40 ° C - outside temperature 7 ° C)
HR MINI 6.0
U.M.
kW
6,22
kW
1,49
W/W
4,17
kW
5,94
kW
1,81
W/W
3,28
W/W
3,78
%
153,1
Inversion cycle with immersion water
°C
l
1,1 x 2
m
m
m
m
3/8" x 2
1/4" x 2
°C
l
m
3
/h
m
W
l
bar
bar
W
l
W
dB(A)
52 - 52
dB(A)
%
89,28
%
153,81
kWh/24h
kg
79 / 134
kg
33 x 2
U.M.
HR MINI 6.0
l
50
l
60
min
21
min
17
l
62
l
76
min
25
min
45
18
HR MINI 8.0
HR MINI 11.0
8,12
11,23
1,96
2,71
4,14
4,14
7,75
10,72
2,42
3,34
3,20
3,21
3,71
3,72
150,3
150,6
A+ / A++
R410A
+ 20 / + 55
2,0
2,0 + 1,1
3
5
15
5
5/8"
5/8" - 3/8"
1/4"
1/4" - 1/4"
-15 / +45
70
3,3
6,2
3 - 45
8
1
3
1500
230V/1/50Hz
M
70
5
58
52 - 58
42
92,81
91,05
153,31
153,56
1/2" M
3/4" M
1,82
70 / 125
79 / 134
55
55 + 33
HR MINI 8.0
HR MINI 11.0
51
52
62
64
18
14
15
11
63
65
77
80
22
16
39
30
HR MINI 16.0
16,24
3,92
4,14
15,50
4,84
3,20
3,71
150,3
2,0 x 2
5/8" x2
1/4" x 2
58 - 58
92,81
153,31
79 / 134
55 x 2
HR MINI 16.0**
54
66
8
7
67
82
10
19

Advertisement

Table of Contents
loading

Table of Contents