1. Normal precautions should be taken to guard against swarf/dust entering isolators and any remaining
debris in the bottom of the box should be removed.
2. All unused sub circuit positions must have an associated blank plate fitted in the box cover. Ensure all
terminal shields are replaced.
3. Appropriate Isolator devices: EMS631N, EMS1001N
4. The EAN Full Metal Box and appropriate devices have been type tested to the following specifications:
Main Switch :
Wall fixing / dimensions
Torque settings and cable capacity
ISOLATOR – 2,5 Nm – 50 mm²
Earth points: 2,0 Nm – M5 bolt for cable lug
Important:
Tighten all connections to the specified torques, including factory made connections.
The terminals are suitable for copper connections ONLY.
Testing of the installation
1. After completion of the installation, it is essential that a test is carried out in accordance with the latest
Edition of the BS7671 (IET Wiring Regulations).
2. It is important that the following are included in 1 above:
Check that all connectors, are fitted correctly and all screw type connections are tightened
sufficiently.
IEC/EN 60947-3
Eaton Electric Limited
Grimshaw Lane
Middleton, Manchester M24 1GQ
United Kingdom
Customer Support Centre
UK tel: +44(0) 8700 545 333
UK fax: +44(0) 8700 540 333
email: ukcommorders@eaton.com
www.eaton.com
© 2015 Eaton Corporation
All Rights Reserved
Form No. IL01900001U
October 2015
Warning – Intellectual Property Rights
Eaton wishes to make it clear that it owns intellectual property
rights in the product which it manufactures (whether or not listed
in this leaflet) and that it will take legal action against any party
found to be manufacturing, using, or selling any article which
infringes the company's intellectual property. All marks in this
document identified with an R symbol or a TM symbol adjacent
to the mark are trademarks of Eaton.
The use to which this product is put and its place of installation is
outside our control.
Particular care should therefore be taken to follow the
instructions given here and to ensure their continued availability
in conjunction with the use of the product.
No responsibility can be accepted by us if these instructions are
disregarded. Further copies of these instructions and information
concerning the installation and proper use of this product can be
obtained by contacting the: Technical Services Department
2

Advertisement

loading

This manual is also suitable for:

Ean2sebdEan4sebd