Whirlpool pedicure spa

Advertisement

Discharge Pump Installation
ON/OFF DISCHARGE SWITCH
WATER LEVEL
Tub
AIR VENT HOSE
L-TRAP
To prevent the possible air lock, B has to higher than A
FAQ
1) Pump hums but does not drain the water out
- Air Lock : Piping elevation must be above discharge pump outlet
so that air can be released
- Turn pump on, wait 5 seconds, turn pump off. Repeat 10 times. If the air is not repleased,
detach attachment pipe and re-attach
Quick Tip: Use a plunger to release the air lock
2) Pump does not turn on
- Check the power source
- Check if the air tubing is properly attached from the switch to the converter box
- Check attachment pipes throughly for debris
3) Noise when turn on
- Foreign object may be lodged - Disassemble and remove debris or particles
MUST BE PLACED HIGHER THAN WATER LEVEL
AIR TUBING
Check Valve must be installed to prevent back flow
ATTACHMENT PIPE
DISCHARGE PUMP
POWER CORD
CONVERTER BOX
A
- Outlet from drain pump must be placed
- Do not use flexible pipe for drain
15
(Optional)
Outlet
B
Main Drain Pipe
on top of the main drain pipe

Advertisement