Site Selection
Minimum clearances when mounting the heater parallel with a ceiling.
165mm
(6.5")
Min.
600mm
600mm
(23.6")
(23.6")
Min.
Min.
910mm (35.4") Min. to surfaces (ie. table tops, etc.)
2100mm (82.7") Min. from floor
3000mm (118.1") Max. from floor (recommended)
Minimum clearances when mounting the heater at an angle to the ceiling.
150mm
(5.9")
Min.
600mm
(23.6")
1500mm
Min.
(59.1")
Min.
910mm (35.4") Min. to surfaces (ie. table tops, etc.)
2100mm (82.7") Min. from floor
3000mm (118.1") Max. from floor (recommended)
Minimum clearances when mounting the heater on A VERTICAL WALL.
240mm (9.4")
Min.
1500mm (59.1")
Min.
105mm
910mm (35.4") Min. to surfaces (ie. table tops, etc.)
(4.1") Min.
Canada 2400mm (94.5") Min. from floor
US 1800mm (70.9") Min. from floor
CEILING
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
CEILING
600mm (23.6") Min.
IR heater, same minimum
clearance requirements
for both ends of heater
installation
CEILING
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
CEILING
600mm (23.6") Min.
IR heater, same minimum
clearance requirements
for both ends of heater
installation
CEILING
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
CEILING
600mm (23.6") Min.
IR heater, same minimum
clearance requirements
for both ends of heater
installation
Wall-mounted
installation
(DIR15A10GR,
DIR18A10GR,
DIR22A10GR,
DIR30A10GR)
Correct Installation
CEILING