Start-Up; Operation - AL-KO INVERTER 2000i Manual

Hide thumbs Also See for INVERTER 2000i:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19
6. Clean and tightly close the oil filling lid.
7. Insert and tighten engine cover

Start-up

Important!
Generator must be safely earthed
The camera symbol on the following pages refers
to the figures on the first pages
Earthing the machine
Important - Electric shock!
Do not use a bare wire for earthing.
Important!
Generator must be safely earthed
Use an earthing wire with a cross-section of at
least 2.5 mm
for earthing
2
Connecting the earthing wire (
1. Press the end of the earthing wire under the nut of
the earthing terminal.(
2. Secure the earthing wire by tightening the nut
3. Connect the other end of the earthing wire to an
earthing spike (e.g. metal rod)
4. Put the earthing spike securely into the soil
Choke (
7)
1. In the case of a cold start, turn the rotary switch into
"CHOKE" position.
2. If the machine is at operating temperature, turn the
rotary switch into "ON" position.
Starting the engine
Important – Danger of poisoning!
Never run the engine in enclosed spaces.
Important – Danger of injury!
Important – Danger of kickback!
Cable starter can return faster to the engine than
the cable can be released.
1. Set the ESC switch to "OFF" (
2. Turn the fuel tank lid bleeder valve to "ON" (
478 067_c
1)
1/1)
8)
9)
3. In the case of a cold start, turn the rotary switch into
"CHOKE" position (
The "CHOKE" position is not necessary, if the
engine is at operating temperature. In this case,
turn the rotary switch to "ON"
Important!
Hold the generator during start-up with one hand
on the handle so that it does not slip or tilt during
the start attempt
4. Pull out cable starter slowly until it is tight.
5. Pull the cable starter briskly, and then allow it to
wind back in slowly (
If the machine still does not start after the second
attempt, follow the instructions for the choke
When starting the engine with ESC "ON" and no
consumers are connected to the generator
the engine is run at ambient temperatures
below 0 °C for 5 minutes at nominal speed
(5000 rpm), so that the engine warms up.
the engine is run at ambient temperatures
below 5 °C for 3 minutes at nominal speed
(5000 rpm), so that the engine warms up.
After this time period, the engine speed is regu-
lated by the ESC to a respective operating speed
depending on the connected devices and the
related load.

Operation

Turn the rotary switch back from "CHOKE" to "ON"
approx. 30 seconds after the start (
Oil warning indicator lamp (red)
If the oil level drops below the minimum, the oil warning
indicator lamp lights up and the engine stops automati-
cally. In order to start the engine again, oil must be added.
Overload indicator lamp (red)
The overload indicator lamp lights up if an overload
caused by a connected electric device is detected, the
inverter control unit overheats or the AC output voltage
increases. AC protection is triggered that stops pow-
er generation in order to protect the generator and all
connected electric devices. The AC indicator lamp
GB
7)
10)
11).
15/1)
(
(
15/2)
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents