Chapter 5: Data Logging Extraction; About Data Logging; Accessing Data Logging; Figure 14 - Hhu Home Screen - Neptune Technology ProCoder R900i Installation And Maintenance Manual

An integrated meter-reading register
Table of Contents

Advertisement

This chapter provides information about data logging.

About Data Logging

The ProCoder™)R900i™ stores interval data for data logging and retrieving this data
through RF activation. You activate the ProCoder)R900i using the Trimble
and R900
The ProCoder)R900i stores consumption in hourly intervals for a rolling total of 96
days, which is equal to 2,304 hourly intervals of consumption. The logged data can be
extracted through radio frequency (RF) activation. The RF activation allows the utility
workers to visit the location and extract the data without physically interacting with the
meter itself. This limits worker exposure to animals or dangerous situations. The
extraction process only takes about 30 seconds. You activate the unit through the
Hand-Held Unit (HHU) connected to the R900 BCT via Bluetooth
sends the activation signal to the ProCoder)R900i which in turn sends the data intervals
to the R900. The data is saved in the HHU.

Accessing Data Logging

Complete the following steps to log data.
1. From the host software home screen on the HHU, click MENU.
ProCoder™)R900
™ Installation and Maintenance Guide
i

Chapter 5: Data Logging Extraction

®
Belt Clip Transceiver (BCT).
Figure 14  – HHU Home Screen
®
®
Nomad
®
. The R900 BCT
19