Installing an LCC
Figure 3
Replacing a DAE2P/DAE3P LCC Module
6
!
CAUTION
If you are replacing a failed LCC, wait at least 30 seconds after
removing the failed LCC before installing the replacement LCC.
1. Gently push the LCC into the enclosure until it is completely seated
in the enclosure midplane (Figure 3 ).
Captive Screw
Installing an LCC
The LCC Power light turns on.
2. Secure the module with the captive screws.
3. Reattach the copper cables (a PRI cable and a possible EXP cable) to
the same connectors from which you removed them (Figure 4 ).
The orientation of the connector for the EXP cable is opposite the
orientation of the connector for the PRI cable.
B
A
E X
P
P R
I
P R
I
E X
P
Captive Screw
#
EMC3181