Digital Input - Emerson XM670K 50 Quick Start Manual

Dual compressor with e2e

Advertisement

Enable Synch
Light Synch
Aux Synch
Stpt Shift Sync
Use Remote Disp
SETPOINT STATUS Set point status
LIGHTS OUTPUT
DEFROST END
PROBE 1 TEMP
PROBE 2 TEMP
PROBE 3 TEMP
PROBE 4 TEMP
FAN PROBE

DIGITAL INPUT 1

DIGITAL INPUT 2
DIGITAL INPUT 3
COMPRESSOR 1
COMP 1 SAFETY
Document Part # 026-4275 Rev 0
©2019 Emerson Climate Technologies Retail Solutions, Inc. This document may be photocopied for personal use.
Visit our website at http://www.emerson.com for the latest technical documentation and updates.
LOF - LAN enable input
synchronization
Lli - LAN light output
synchronization
LAU - LAN aux output
synchronization
LES - LAN setpoint shift
synchronization
LSd - Use display from LAN Not used.
Reports light relay output
status
Defrost End State
dP1 - Probe 1 temperature Reports temperature probe 1 status on application status screen. Update
dP2 - Probe 2 temperature Reports temperature probe 2 status on application status screen. Update
dP3 - Probe 3 temperature Reports temperature probe 3 status on application status screen. Update
dP4 - Probe 4 temperature Reports temperature probe 4 status on application Status screen. Update
Evaporator Fan Probe
Value
Reports digital input state
1
Reports digital input state
2
Reports digital input state
3
Reports comm 1 relay
output status
Reports status if comp 1
safety dig input
Table 2 - XM670K_50 Property Help Explanations
Not used.
Not used.
Not used.
Not used.
Reports active setpoint status on application Status screen. Update rate:
10 - 30 seconds. Can be pointed to for use in other applications. Logging
set by default. User can disabled logging.
Reports light relay output status on application Status screen. Update
rate: 10 - 30 seconds. Can be pointed to for use in other applications.
Logging set by default. User can disable logging.
Reports active setpoint status on application Status screen. Update rate:
10 - 30 seconds. Can be pointed out for use in other applications. Logging
set by default. User can disable logging.
rate: 10 - 30 seconds. Can be pointed out for use in other applications.
Logging set by default. User can disable logging.
rate: 10 - 30 seconds. Can be pointed out for use in other applications.
Logging set by default. User can disable logging.
rate: 10 - 30 seconds. Can be pointed out for use in other applications.
Logging set by default. User can disable logging.
rate: 10 - 30 seconds. Can be pointed out for use in other applications.
Logging set by default. User can disable logging.
Reports configured fan probe value. If not set, a reading of
-32768 will log. Can be pointed out for use in other applications. Logging
set by default. User can disable logging.
Reports digital input 1 status on application Status screen. Update rate: 10
- 30 seconds. Can be pointed out for use in other applications. Logging set
by default. User can disable logging.
Reports digital input 2 status on application Status screen. Update rate: 10
- 30 seconds. Can be pointed out for use in other applications. Logging set
by default. User can disable logging.
Reports digital input 3 status on application Status screen. Update rate: 10
- 30 seconds. Can be pointed out for use in other applications. Logging set
by default. User can disable logging.
Reports compressor 1 relay output status on application Status screen.
Update rate: 10 - 30 seconds. Can be pointed out for use in other
applications. Logging set by default. User can disable logging.
Reports compressor 1 safety digital input status on application Status
screen. Update rate: 10 - 30 seconds. Can be pointed out for use in other
applications. Logging set by default. User can disable logging.