DI 1 Config
Probe 1 Offset
Probe 2 Config
Probe 2 Offset
Probe 3 Config
Probe 3 Offset
Probe 4 Config
Probe 4 Offset
DI 1 Delay
DI 2 Polarity
DI 2 Config
Document Part # 026-4275 Rev 0
©2019 Emerson Climate Technologies Retail Solutions, Inc. This document may be photocopied for personal use.
Visit our website at http://www.emerson.com for the latest technical documentation and updates.
i1F - Digital input 1
configuration
OF1 - P1 calibration
P2C - Probe 2
configuration
OF2 - P2 calibration
P3C - Probe 3
configuration
OF3 - P3 calibration
P4C - Probe 4
configuration
OF4 - P4 calibration
d1d - Input delay or alarm
delay
i2P - Digital input 2
polarity
i2F - Digital input 2
configuration
Table 2 - XM670K_50 Property Help Explanations
Selects 1st Digital Input configuration for sequence. When set to Door
Switch, the device will obey E2 property setting Door Sw Mode (odC)
and shut down refrigeration and/or fan relay outputs, and resume normal
operation when the door switch deactivates. If Door Switch stays in an
active state for longer than the DI 2 DELAY (did) setting, the device will
alarm and the refrigeration and/or fan relay outputs will turn back ON if
DOOR ALM RESTART (rrd) is set to YES. The local display will show dA.
When set to Light Switch, the change of state of the digital input will turn
the light ON or OFF, depending on how polarity and delay are set. If Light
Switch is chosen, the Lights On property of the inputs tab has to be
mapped (pointed) as an input from the same application and its
respective digital input 1 output property in the Outputs tab. If set to
Device On/Off, the change of state of the digital input will turn the device
ON or OFF, depending on how polarity and delay are set. If Device On/Off
is chosen, the Device Disable property in the inputs tab has to be mapped
(pointed) as an input from the same application and its respective digital
input 1 output property in the Outputs tab. If Set Point Shift is chosen,
the SetPoint Shift property in the Inputs tab has to be mapped (pointed)
as an input from the same application and its respective digital input 1
output property in the Outputs tab.
Setting used to adjust possible offset of probe 1.
Selects the type of probe used for probe 1.
Setting used to adjust possible offset of probe 2.
Selects the type of probe used for probe 2.
Setting used to adjust possible offset of probe 3.
Selects the type of probe used for probe 3.
Setting used to adjust possible offset of probe 4.
Sets delay of activation for the input configured.
CL = The input is activated by closing the contact;
OP = The input is activated by opening the contact.
Selects 2nd Digital Input configuration for sequence. When set to Door
Switch, the device will obey E2 property setting Door Sw Mode (odC)
and shut down refrigeration and/or fan relay outputs, and resume normal
operation when door switch deactivates. If Door Switch stays in active
state for longer than DI 1 DELAY (did) setting, the device will alarm and
the refrigeration and/or fan relay outputs will turn back ON if DOOR ALM
RESTART (rrd) is set to YES. The local display will show dA. When set to
Light Switch, the change of state of the digital input will turn the light on
or off, depending on how polarity and delay are set. If Light Switch is
chosen, the Lights On property of the Inputs tab has to be mapped
(pointed) as an input from the same application and its respective digital
input 2 output property in the Outputs tab. If set to Device On/Off, the
change of state of the digital input will turn the device ON or OFF,
depending on how polarity and delay are set. If Device On/Off is chosen,
the Device Disable property in the Inputs tab has to be mapped (pointed)
as an input from the same application and its respective digital input 2
output property in the Outputs tab. If Set Point Shift is chosen, the
SetPoint Shift property in the Inputs tab has to be mapped (pointed) as
an input from the same application and its respective digital input 2
output property in the Outputs tab.