TM00358 Rev. A
2.8 EON MENU
The EON menu (electro-optic narrow) provides status information and controls for the EON sensor. Operators can
also access a Level 3 Miscellaneous sub menu for additional diagnostic data in the form of sensor component
temperatures.
LEVEL 2 - EON
MODE
ALARMS
FOV
FOCAL LENGTH
FOCUS
SENSITIVITY
TEMP STATUS
FILTER
LEVEL
SCENE SETUP
Table 2-9 Status Information and Controls in the Level 2 EON Menu
Field
LEVEL
0 to 100
SCENE SETUP
DEFAULT
HIGH
LOW
MISC
ALARMS
BIT
DONE
FOV
Daylight: 0.28°,
Lowlight: 0.30°
FOCAL LENGTH
1000 mm
L-3 WESCAM
All Rights Reserved
OPERATIONAL
OK
0.28 deg
1000
mm
150
AUTO
OK
COL
50
DEFAULT
MISC
ALARMS
BIT
Figure 2-25 EON Menu
Values
VALUE FIELDS
Sets the pedestal black level. Default value is 50.
Optimizes camera for general purpose setup.
Optimizes camera for high-contrast scenes.
Optimizes camera for low-contrast scenes.
ACTION FIELDS
–
Displays Miscellaneous menu.
–
Displays Alarms page with BIT test results for the EON sensor.
–
Initiates an EON BIT.
–
Exits menu.
STATUS INDICATORS
Current horizontal FOV in degrees.
Current focal length in millimeters.
LEVEL 2 - EON
LEVEL 3 - MISCELLANEOUS
TEMPERATURES
AMBIENT 1
AMBIENT 2
PROCESSOR
LENS
CAMERA
LL CAMERA HEAD
LL CAMERA BODY
LL EXT CAMERA BODY
DONE
−
Levels 2 and 3
Description
Chapter 2 - EON Menu
22.4
deg C
21.8
deg C
37.6
deg C
22.9
deg C
35.9
deg C
31.1
deg C
25.2
deg C
30.4
deg C
DONE
October 2007
37
Need help?
Do you have a question about the MX-15i and is the answer not in the manual?