Chapter 2 - IR Menu
Table 2-8 Status Information and Controls in the Level 2 IR Menu (Continued)
Field
SCENE SETUP
DEFAULT
Note: Initiate a 1-
HIGH
Point
calibration for
LOW
every scene
change.
CALIBRATE
MISC
ALARMS
BIT
DONE
FOV
0.36°, 1.09°,
5.43°, 26.67°
FOCAL LENGTH
27, 135, 675,
2024
FOCUS
3 m to Infinity
SENSITIVITY
AUTO
MAN
LEVEL
AUTO
MAN
TEMP STATUS
COOLING
OK
POLARITY
BLACK HOT
WHITE HOT
October 2007
36
Values
Optimizes camera for general purpose setup.
Optimizes camera for high-contrast scenes.
Optimizes camera for low-contrast scenes.
ACTION FIELDS
Initiates calibration.
Displays Miscellaneous menu.
Displays Alarms page with BIT test results for the IR sensor.
Initiates an IR BIT.
Exits menu.
STATUS INDICATORS
Current optical horizontal FOV in degrees.
Current focal length in mm. VNFOV has a 2x E-Zoom applied.
Focus position, expressed as an estimated distance to the object that sensor is
focused on. Units = meters.
Note: This is a very crude calibration and therefore should not be taken as a
target distance.
System has been enabled for automatic control of image brightness.
Current value for manual sensitivity. Operators can increment the sensitivity to
control image brightness from the Hand Controller.
System has been enabled for automatic level control.
Current value for manual level. Operators can increment the level to control
image contrast from the Hand Controller.
Sensor disabled because internal operational temperature is above or below
limits.
Sensor at operational temperature.
Hottest objects in video appear black, coolest appear white.
Hottest objects in video appear white, coolest appear black.
Description