Summary of Contents for Keysight Technologies E36300 Series
Page 1
Keysight E36300 Series Programmable DC Power Supplies This manual provides the documentation for the following instruments: - E36311A - E36312A - E36313A Security Guide...
Page 2
FAR 27.401 or DFAR laration of Conformity. could result in personal injury or death. 227.7103-5 (c), as applicable in any Do not proceed beyond a WARNING technical data. notice until the indicated conditions are fully understood and met. Keysight E36300 Series Security Guide...
..........18 Keysight E36300 Series Security Guide...
Page 4
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight E36300 Series Security Guide...
Page 5
Keysight E36300 Series Programmable DC Power Supplies Security Guide Getting Started Warranty Where to Find the Latest Information Is your product software up-to-date? Contacting Keysight Sales and Service Offices Products Covered by this Document Security Terms and Definitions Instrument Memory...
This Keysight Technologies product is warranted against defects in material and workmanship for a period of three years from the date of shipment. During the warranty period, Keysight Technologies will, at its option, either repair or replace products that prove to be defective. For warranty service or repair, this product must be returned to a service facility designated by Keysight Technologies.
In any correspondence or telephone conversation, refer to the instrument by its NOTE model number and full serial number. With this information, the Keysight representative can determine whether your unit is still within its warranty period. Keysight E36300 Series Security Guide...
NOTE saved is properly backed up before attempting to clear any of the instrument memory. Keysight Technologies cannot be held responsible for any lost files or data resulting from the clearing of memory. Be sure to read this document entirely before proceeding with any file deletion or memory clearing.
(DSS). These requirements are specified in the “Clearing and Sanitization Matrix” in Section 5.2.5.5.5 of the ISFO Process Manual. Secure Erase is a term that is used to refer to either the clearing or Secure Erase sanitization features of Keysight instruments. Keysight E36300 Series Security Guide...
128 kByte information. Main board microcontroller Channel 2 main board Microprocess Channel 2 main Channel 2 microcontroller temporary or execution board Power cycle (RAM) execution data code/data microcontroller 16 kByte Keysight E36300 Series Security Guide...
Page 11
128 kByte information. Main board microcontroller Channel 2 main board Microprocess Channel 2 main Channel 2 microcontroller temporary or execution board Power cycle (RAM) execution data code/data microcontroller 16 kByte Keysight E36300 Series Security Guide...
Page 12
Power cycle (RAM) execution data code/data microcontroller 16 kByte Main board microcontroller Channel 1 main board Microprocess Channel 1 main Channel 1 microcontroller temporary or execution board Power cycle (RAM) execution data code/data microcontroller 16 kByte Keysight E36300 Series Security Guide...
Page 13
IO controller IO controller Microprocess microcontroller IO controller microcontroller temporary or execution Power cycle (RAM) microcontroller execution data code/data 256 KByte Microprocess Main RAM Temporary execution data or execution Front panel Power cycle (SDRAM) 16MB code/data Keysight E36300 Series Security Guide...
Page 14
316Byte security code, and information. calibration message User data, IO Instrument state EEPROM configuration, instrument and setting User-saved Sanitize – configuration and Front panel (EEPROM) data instrument state 127.6KB Table 1-2. information. Keysight E36300 Series Security Guide...
Description and This memory is used to identify the assembly and store factory calibration purpose data and option configuration data. Size 127.6 kBytes Memory clearing Use the same procedure as documented below in Memory sanitization. Keysight E36300 Series Security Guide...
Page 16
June 28, 2007 DSS Memory Clearing and Sanitization Matrix. This memory cannot be removed without damaging the instrument. The user Memory removal may remove the front panel assembly on which the memory chip resides. Keysight E36300 Series Security Guide...
If the instrument is not able to power on, the user information cannot be cleared using the front panel or the remote interface. The only choice in this situation is to take manual steps to remove any user information that may be present. Keysight E36300 Series Security Guide...
2 ISFO Process Manual for the Certification and Accreditation of Classified Systems under the NISPOM Defense Security Service. DSS-cleared industries may request a copy of this document via email, by following the instructions at: http://www.dss.mil/isp/odaa/request.html Keysight E36300 Series Security Guide...