SBM XFR Series Installer's Instructions

SBM XFR Series Installer's Instructions

Gas infrared heaters

Advertisement

Quick Links

GAS INFRARED HEATERS
XFR INSTALLER
INSTRUCTIONS
N° 05000485/0
Hight radiant factor luminous heater
Stainless steel burners
Stainless steel body
Electronic ignition
Thermocouple flame control
Manufacturer :
Agent :
SBM
3 cottages de la Norge
1312
21490 CLENAY
France
http : //www.sbm-international.net
1

Advertisement

Table of Contents
loading

Summary of Contents for SBM XFR Series

  • Page 1 GAS INFRARED HEATERS XFR INSTALLER INSTRUCTIONS N° 05000485/0 Hight radiant factor luminous heater Stainless steel burners Stainless steel body Electronic ignition Thermocouple flame control Manufacturer : Agent : 3 cottages de la Norge 1312 21490 CLENAY France http : //www.sbm-international.net...
  • Page 2: Table Of Contents

    2.11 Start-up ....................20 to 22 3. RECEIPT OF INSTALLATION Page 4. MAINTENANCE Page 5. REPAIRS Pages 25 to 28 6. CHANGING THE GAS USED Page GENERAL - In the process of continuous improvement, SBM products may be modified without notice.
  • Page 3: Product Specification

    1. PRODUCT SPECIFICATION Hight radiant factor grid + fins 1.1 Description Thermocouple (flame control) Burner End plate Gas block box Ignition deflector Electrode (for single speed heater) (ignition) Air insulation inside a double metal skin Fixing brackets for square tubes 25 mm, gap 250 mm Preheating burners chamber (exhaust gases recirculation) Ballon grid socket...
  • Page 4: Technical Specifications

    1.2 Technical specifications GAS : G20 (Natural gas) - Category : I 2H GB/IE MODEL XFR 16 XFR 20 XFR 20-2 XFR 24 XFR 24-2 XFR 32 XFR 32-2 XFR 48-2 XFR 64-2 1312 CL 5522 Certificat number Class NOx Weight (kg) 14.60...
  • Page 5: Xfr Heater Dimensions

    1.3 XFR heater dimensions XFR 16 XFR 20, XFR 20-2, XFR 24, XFR 24-2, XFR 32, XFR 32-2, XFR 48-2 and XFR 64-2 MODEL A (mm) B (mm) C (mm) D (mm) XFR 20 XFR 20-2 XFR 24 XFR 24-2 XFR 32 XFR 32-2 XFR 48-2...
  • Page 6: Installation

    Before installation, check that the local conditions of supply, gas type / pressure and equipment settings are compatible. 2.1 Rules and regulations  SBM infrared heaters are approved.  The premises must be ventilated in accordance with the norm EN13410.
  • Page 7: Diagram Of A Standard Installation Single Speed

    2.2 Diagram of a standard installation single speed. Main solenoid valve Flexible hose BA connector XFR single speed heater Governor ( ) Individual valve 3 x 0.75mm² Sensor cable (to be ordered separately) Main valve Sensor Control unit (supplied with control modul) 230V ~ L + N + Pe Filter...
  • Page 8: Unpacking And Checking Of Equipment

    3.60 XFR 20 / XFR 20-2 3.80 XFR 24 / XFR 24-2 4.10 XFR 32 / XFR 32-2 4.50 XFR 48-2 5.00 XFR 64-2 5.50  MINIMUM COMFORT HEIGHTS : refer to the specific SBM case study for each project.
  • Page 9  Examples of fixtures to be supplied by the installer : XFR 48-2 = XFR 24 + XFR 24 + (2 XFR 24) BEAM XFR 64-2 = XFR 32 + XFR 32 + (2 XFR 32) BEAM If heaters will be fit with ballon grids, grids must be mounted before the 2 heaters assembly.
  • Page 10 XFR 48-2 XFR 64-2 A (mm) B (mm) C (mm) 1053 1300 D (mm) 1473 1720 Weight (kg) 35.10 42.30...
  • Page 11 FLEXIBLE HOSE G1/2f 1250mm (supplied by SBM) 200 min Dimensions in mm.  Example of SBM multi-directional bracket for XFR 16 to XFR 32-2 VALVE DN15 SS PDC E/S Rp1/2 (supplied by SBM) Governor DF64 G1/2 … (supplied by SBM)
  • Page 12 To be defined according to the weight XFR Heater Steel tube. Size to be adapted according to weight and length. VALVE DN15 SS PDC E/S Rp1/2 (supplied by SBM) GOVERNOR DF64 G1/2 … (supplied by SBM) RP3 (single speed) RP32 (double speed)
  • Page 13  Example of SBM multi-directional bracket for XFR 48-2 and XFR 64-2 XFR 48-2 : 548 XFR 64-2 : 672 6 holes Ø9 RP32 (double speed) (supplied by SBM) VALVE DN15 SS PDC E/S Rp1/2 (supplied by SBM) BRACKET XFR (supplied by SBM) GOVERNOR DF64 G1/2 …...
  • Page 14: Accessories

    2.6 Accessories  Grilles for protecting XFR heaters from balls and other flying objects PROTECTIVE GRILLE XFR 16 PROTECTIVE GRILLE XFR 20 PROTECTIVE GRILLE XFR 24 PROTECTIVE GRILLE XFR 32 (supplied by SBM)
  • Page 15 XFR 48-2 : 2 x PROTECTIVE GRILLE XFR 24 XFR 64-2 : 2 x PROTECTIVE GRILLE XFR 32...
  • Page 16: Inclination Of Heaters

    Where safety clearances cannot be respected, heat-protection must be provided above the heaters. 2.8 Inclination of heaters  Inclination "I" = at least 10° (check SBM survey) BA BLOCK IN LOW POSITION I = 10 to 35° ...
  • Page 17: Gas Connection

    2.9 Gas connection BEFORE INSTALLATION, CHECK THAT LOCAL CONDITIONS OF SUPPLY, GAS TYPE / PRESSURE AND EQUIPMENT SETTINGS ARE COMPATIBLE.  Gas supply piping must not produce any stress on the injector block (Use preferably a metalic flex 12 Gf) ...
  • Page 18 Double speed installation VALVE DN15 SS PDC E/S Rp1/2 UNION FITTING R1/2m-G1/2m DF64 G1/2 G31-37 4KG/H DF64 G1/2 G20-20 3M3/H FLEXIBLE HOSE G1/2f 1250mm SLEEVE F/F G1/2 VITON WASHER G1/2 T FITTING MALE G1/2 1500mm flexible hoses available for XFR 48-2 and XFR 64-2. ...
  • Page 19: Electrical Connections

    NEUTRAL brown wire: LIVE Control unit to sensor Use the coaxial cable supplied by SBM. (in 20m, 60m or 300m roles) Number of RP3 and units : 1 RP3 per type XFR 16, XFR 20, XFR 24 and XFR 32.
  • Page 20: Start-Up

     Wire RP3’s as shown in the diagram below. N/L1 N/L1 PRECEDING RP3 FOLLOWING RP3 3x0.75 mm 3x0.75 mm Ph/L2 Ph/L2 Fuse 0.25A (to be ordered separetely) Ph/L2 N/L1 XFR HEATER single speed  Wire RP32’s as shown in the diagram below. 100% N/L1 N/L1...
  • Page 21  Gas-tightness test : a) Nitrogen or dry air at 1.5 times more pressure than gas operating pressure P b) Turn off the nitrogen or dry air supply and wait 15 minutes. c) Check the pressure gauge after 2 hours (must stay fixed). d) If not, detect leaks with a foaming product, fix them and repeat the operation Solenoid valve...
  • Page 22 d) Injection pressure p check * The injection pressure of each heater p must be set to the value indicated in the corresponding tables §1.2 page 4. Inlet pressure p (pressure point) * Procedure : . Unscrew the pressure test point screw (2 or 3 turns) .
  • Page 23: Receipt Of Installation

    3. RECEIPT OF INSTALLATION  TO BE PERFORMED BY THE FITTER IN THE PRESENCE OF THE CUSTOMER.  Check that the gas type and pressure comply with the type of heater installed (see rating plate)  Check that an individual valve is installed prior to each heater. ...
  • Page 24: Maintenance

    4. MAINTENANCE LIST OF OPERATIONS TO BE PERFORMED DURING THE ANNUAL MAINTENANCE VISIT.  Removal of dust from heaters - on site, without disassembly, heaters off and cold. JOINTS COMPRESSED AIR :3 to 5 bar MAX DO NOT BLOW AIMING AT JOINTS BETWEEN CERAMIC PLATES (risk of damaging the burner) ...
  • Page 25: Repairs

    5. REPAIRS Problem on a single heater.  First, check compatibility of heaters with the gas type and pressure. ONE HEATER LIGHTS AND ONE HEATER DOES GOES OUT AFTER NOT LIGHT 45 seconds Check thermocouple No spark Spark properly tightened on injector block Check individual Check...
  • Page 26  Problems on a group of heaters. First, check compatibility A GROUP OF HEATERS of heaters with the gas DO NOT LIGHT type and pressure. Spark No spark Control module Control module Check main gas valve open Module displays : Module displays : Check power supply (Main breaker)
  • Page 27  XFR heater spare parts. WITH ALL SPARE PART ORDERS, PLEASE INDICATE : (see rating plate) : - Type / serial number of the heater. - Gas type. - Operating pressure. SPARE PARTS BR 10 XFR 96 (burner for XFR 20 and XFR 20-2) BR 12 XFR 96 (burner for XFR 24, XFR 24-2 and XFR 48-2) BR 16 XFR 96...
  • Page 28: Changing The Gas Used

    6. CHANGING THE GAS USED (must be down by a skilled technician)  Gas and pressure. FAMILY OPERATING PRESSURE I 2H 20 mbar I 3P 37 mbar  Change of gas For any further information please contact your SBM agent.
  • Page 29 COMMISSION REGULATION (EU) 2015/1188 Requirements for product information applicable to commercial local space heaters Luminous heaters XFR Model identifier 20-2 24-2 32-2 48-2 64-2 Type of heating Luminous heaters Fuel Gaseous Space heating emissions emissions (mg/kWh < 50 Heat input Nominal heat input (kW 11,4 11,4...