SBM 2 ZRFA Technical Instructions

Gas ceramic heating, gas heating for poultry and livestock

Advertisement

TECHNICAL INSTRUCTIONS
GAS HEATING FOR POULTRY AND LIVESTOCK
1. TECHNICAL SPECIFICATIONS
2. SAFETY INSTRUCTIONS
3. IGNITING OF HEATERS
4. SHUTT-OFF OF HEATERS
5. MAINTENANCE
6. GAS CONVERSION
7. SPARE PARTS
Manufacturer :
SBM
3 cottages de la Norge
21490 CLENAY - FRANCE
GAS CERAMIC HEATING
FA HEATERS
N° 05000077/6
1312
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2 ZRFA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SBM 2 ZRFA

  • Page 1 GAS CERAMIC HEATING FA HEATERS TECHNICAL INSTRUCTIONS N° 05000077/6 GAS HEATING FOR POULTRY AND LIVESTOCK 1. TECHNICAL SPECIFICATIONS 2. SAFETY INSTRUCTIONS 3. IGNITING OF HEATERS 4. SHUTT-OFF OF HEATERS 5. MAINTENANCE 6. GAS CONVERSION 7. SPARE PARTS Manufacturer : 1312 3 cottages de la Norge 21490 CLENAY - FRANCE...
  • Page 2: Technical Specifications

    1. TECHNICAL SPECIFICATIONS : Refer to the heater rating plate attached to the filter support see example opposite : MODEL ZRFA ZRFA ZRFA ZRFA ZRFA ZRFA certificate number 1312 AR 1201 Weight (kg) 1.55 1.70 2.10 2.50 3.00 3.50 6.50 7.80 Nominal heat flow 0.80...
  • Page 3: Safety Instructions

    2. SAFETY INSTRUCTIONS : THE HEATERS SHOULD BE INSTALLED AND MAINTAINED IN SUFFICIENTLY VENTILATED PREMISES BY A QUALIFIED INSTALLER ACCORDING TO CURRENT SAFETY REGULATIONS. NOT AUTHORISED FOR USE IN DOMESTIC PREMISES. TO BE INSTALLED IN COMPLIANCE WITH CURRENT REGULATIONS AND IN SUFFICIENTLY VENTILATED PREMISES 2.1 HEATER INCLINATION 2/3 ZRFA...
  • Page 4 Table of minimum safety heights with respect to the ground : MODEL MINI. HEIGHT (m) 2 ZRFA 0,30 3 ZRFA 0,30 6 ZRFA 0,50 8 ZRFA 0,50 12 ZRFA 0,50 16 ZRFA 1,00 min. height 212 FA 1,00 216 FA 1,00 For pratical hanging heights, please contact your SBM representative.
  • Page 5 3. IGNITING THE HEATERS : 3.1 CONNECTING THE GAS HEATER 230V AC RCD 16A - 30mA (Residual Current Device) Ground terminal Sensor cable VisioLon Elv-T Enclosure KIT MODULE ENCLOSURE 2 ZONES RP3 + 1 x 0.25A fuse G6A or G10A Main gas valve G31 (Propane) 1.5 bar...
  • Page 6: Maintenance

    4. SHUT-OFF OF HEATERS : Close the main gas valve. Switch off the installation power supply. 5. MAINTENANCE : ONCE A WEEK (or more frequently if the flame becomes blue): - remove the filter box. - remove the dust from the filter media.
  • Page 7: Gas Conversion

    G31 (PROPANE) 148 mbar GB/IE/TR G20 (NATURAL GAS) 148 mbar The equipment is adjusted for the type of gas and the pressure as displayed on the rating plate. For any change of the gas used, please contact your SBM representative.
  • Page 8: Spare Parts

    FOR ANY SPARE PARTS ORDER, PLEASE SPECIFY : - heater type and serial number. - type of gas. - operating pressure. This information is displayed on the rating plate, attached to the heater. PIECE Ref. SBM Cond THERMOCOUPLE 9802001 MAGNETIC HEAD 9803001 10 MEDIAS 115...
  • Page 10 TO BE DISPLAYED NEXT TO THE CONTROL UNIT...
  • Page 11: A U T O M A T I C R E G U L A T I O N

    - check condition of ceramic plaques (visual check). - check the heater attachment. - check accessory seals. Manufacturer : SBM Installer's stamp : 3, Cottages de la Norge 21490 CLENAY - FRANCE...