Approved for use with heater models 530 and 530 insert only
Table of Contents

Advertisement

Available languages

Available languages

ZERO CLEARANCE APPLICATIONS WITH 530IN/IP ONLY
(539AFBv2, 539AFPv2 and 550CPAv2 only)

Hearth Requirements

All installations will require a hearth or floor, flush with
the bottom of the heater, to support the weight of the
cast iron plate and to ensure the removable hearth
fender rests at the proper height.
A non-combustible hearth is not required in front of this
appliance.

Floor Requirements

The 530 heater is approved for installation directly
on any combustible material other than soft flooring
material such as carpet or vinyl.
Dimensions & Clearances — 539 and 550 Arch fronts (539 Windsor Arch shown here)
39"
Fixing Points (4)
31"
Casting Tolerances
Due to the nature of cast iron, dimensional consistency
may vary from one unit to the next and some variation
in surface finish and flatness is to be expected. We have
done our best to control and make allowance for this;
however some variation is inevitable.
'X'
13-1/8"
Mantel
11-1/8"
4"
'Y'
Min. 36" to
combustible
materials
4-1/2"
This shaded area of
the cast plate
(outside of arch)
may be covered with
max 3/4" thick
combustible material
such as wood

Mantel Requirements

The Arch Fronts series is designed to install with
combustible mantels provided clearances are
maintained as indicated in the Dimensions and
Clearances, and Framing diagrams below and on the
following pages. The 539 and the 550 back plate may
also be installed without a mantel provided listed
clearances are maintained. Be aware that although
safe, some combustible materials and finishes at the
listed clearances may, over time, discolor, warp, or show
cracks. Care should be taken when choosing materials—
consult your fireplace dealer.
6-5/8"
Outer
dia.
Cast Plate
ZC Stand-offs
Top
Max 8" deep mantle leg
Outlet
at edge of protruding arch
'X'
1" - 6"
7" - 8"
9" - 12"
12" +
Note: The 549 Windsor Arch front is intended for insert
applications only and does not include the stand-
offs and insulation pads required for zero clearance
applications. See section Insert Applications.
26"
20"
Top
Outlet
4"
1"
Mantel Clearances
'Y'
34"
36"
38"
38" + 1" for every
inch beyond 12"