Speed Reference Selection; Speed Comp Stop Threshold; Force Auto Restart; Ext1 Speed Ref1 - ABB ACS560 Quick Installation And Start-Up Manual

General purpose drives standard control program
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

64 Parameter listing
Index
Name
21.31
Speed compensated stop
delay
21.32

Speed comp stop threshold

21.34

Force auto restart

22 Speed reference selection

22.01
Speed reference unlimited
22.11

Ext1 speed ref1

Zero[0]
EN
AI1 scaled[1]
HI
AI2 scaled[2]
22.12
Ext1 speed ref2
22.13
Ext1 speed function
Ref1[0]
Add (ref1 + ref2)[1]
22.18
Ext2 speed ref1
22.19
Ext2 speed ref2
22.20
Ext2 speed function
22.21
Constant speed function
Bit
0
Range/List
0.00...1000.00
0...100
Disable[0], Enable[1]
-30000.00...30000.00
0...2, 4, 5, 8, 9, 15...19
FB A ref1[4]
EFB ref2[9]
FB A ref2[5]
Motor poten-
tiometer[15]
EFB ref1[8]
PID[16]
See parameter 22.11
Speed ref safe
0...5
Sub (ref1 - ref2)[2]
Mul (ref1 × ref2)[3]
See parameter 22.11
Speed ref safe
See parameter 22.11
Speed ref safe
See parameter 22.13
Ext1 speed function
0b0000...0b1111
Name
Bit
Constant
1
speed mode
Unit
s
%
-
rpm
-
Frequency in-
put[17]
Control panel
(ref saved)[18]
Control panel
(ref copied)[19]
-
-
Min (ref1, ref2)[4]
Max (ref1, ref2)[5]
-
-
-
-
Name
Bit
Direction en-
2...15
able
Default
0.00
10
Disable[0]
0.00
AI1 scaled[1]
Other...
Zero[0]
Ref1[0]
Zero[0]
Zero[0]
Ref1[0]
0b0001
Name
Reserved

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents