In this mode there are 7 digits (five whole numbers and two decimals). The value that must
be introduced is the pulses per unit factor given on the label of the COVOL or turbine.
Depending on the volume units, the k factor should be programmed as follows:
1) litres: the k factor will be directly the value on the flowmeter label.
2) m
3
: the k factor should be multiplied by 1000.
3) U.S. gallons: the k factor should be multiplied by 3.785.
To introduce the required values, pushing the push button marked with the arrow pointing
upwards, the blinking digit will increase. Once the desired value of the digit is achieved, by
pressing the push button marked with the arrow pointing left, the blinking digit will be the
next digit to be modified. On the seventh digit, by pressing this push button, the blinking digit
will return to the first digit.
When the k factor is programmed, by pushing the two push buttons PROG for at least 2
seconds, the value will be saved into memory and the instrument will return to normal working
mode. Again, if the RESET push button is pressed then the instrument will return to normal
working mode without making any changes in the k factor.
NOTE: During the programming process, the converter increases its power consumption. In
order to optimise the battery life, if during 30 seconds no push buttons are pressed, the
converter will return to the normal working mode. In this case the data in the memory will not
be changed.
4.2

Reset

The partial totalizer can be reset in two ways:
1) By pushing the RESET push button during two seconds the counter will be set to zero.
2) Without removing the plastic front cover by holding a magnet horizontally just below the
arrow pointing upwards for two seconds.
Magnet