SAFETY INSTRUCTIONS FOR THE OPERATOR/USER
The regulations in force, the local laws and safety regulations must be observed.Eliminate any dangers relating to electricity. Leakage
of hazardous pumped liquids (e.g. explosive, poisonous, boiling liquids) must be managed in such a way that they do not pose a danger
to persons or to the environment. Observe the regulations in force.
AUTONOMOUS CHANGES AND PRODUCTION OF SPARE PARTS
Le modifiche alla macchina sono consentite solo in accordo con il produttore. I pezzi di ricambio originali e gli accessori autorizzati dal
produttore garantiscono la sicurezza. L'uso di altri pezzi può invalidare la responsabilità per le conseguenze che ne dovessero derivare.
UNAUTHORISED MODES OF OPERATION
Changes to the machine are only permitted in agreement with the manufacturer. Original spare parts and accessories authorised by the
manufacturer ensure safety. The use of other parts may invalidate liability for any possible consequences.
MODALITÀ DI FUNZIONAMENTO NON CONSENTITE
Safety of operation of the machine is only guaranteed by correct usage that complies with the provisions. The limit values given in the
"Technical specifications" chapter must not be exceeded under any circumstances.
This appliance can be used by children over 8 years of age, by persons with a physical, sensory or mental disability, persons with
insufficient experience and knowledge if they are being supervised or have been instructed on the use of the appliance and where they
have understood the resulting dangers involved. Children are not permitted to play with the appliance. Cleaning and maintenance of the
unit cannot be performed by children without supervision.
CHAPTER 2
TECHNICAL DATA
• Pump nominal power
0.37-2.2KW
• Electrical power supply: ~1 x 110- 230 V
• P.max 0.8 MPa
• Frequency: 50/60Hz
• Maximum current: 16 A
CHAPTER 3
DESCRIPTION
DIGITAL PT8 is an electronic pressure switch with integrated digital pressure gauge that includes instantaneous reading of the
absorbed current.
The device allows control of the start and stopping of a single-phase pump up to 2.2 kW (3 HP). The pressure is easily adjustable via
the control panel. The wiring is similar to a traditional electromechanical pressure switch. DIGITAL PT8 can operate as a differential
pressure or reverse pressure switch and controls and manages overcurrent, dry running and rapid operation cycles.
CLASSIFICATION AND TYPE
According to IEC 60730-1 and EN 60730-1 this device is an independent electronic device, with class A programming and type 1B action
(micro-disconnection). Operating value: I<30%I acquired. Pollution degree 2 (clean environment). Assigned pulse voltage : cat II /
2500V. Ball test temperatures: (75ºC) and PCB (125ºC) EMC
• Degree of protection: IP55
• Max. water temperature 50ºC
• Max. ambient temperature: 60ºC
• Operating pressure 0.5÷7 bar
• Stopping range 1÷8 bar
• Maximum differential 7.5 bar
• Minimum differential (adjustable):
0.5÷1.5 bar
• Default configuration (operating/
shutdown) 3/4 bar
• Water mains connection G 1/4" F
• Net weight (without cables) 0.3 kg
EN