TROUBLESHOOTING
Your control system is designed to provide years of trouble-free pool and spa
enjoyment. However, if at any time your system behaves erratically, consult the
following Check List, which should help alleviate any problems caused by operator
error. If you are still unable to solve your particular symptom, refer the situation
to a qualified pool service company.
NOTHING OPERATES :
1. Check all circuit breakers at electrical subpanel.
2. Check 3 amp circuit breaker which is located above FILTER TIMER Dial in
Power Center. A tripped circuit breaker is indicated by a white tab.
3. If circuit breaker continues to trip, refer to a qualified service company.
FILTER PUMP DOES NOT OPERATE :
1. Check that FILTER TIMER Dial in Power Center is programmed on, and
that FILTER PUMP Service Switch in not in the "OFF" position.
2. Check filter pump circuit breaker at electrical subpanel.
3. Filter pump may require servicing.
POOL CLEANER DOES NOT OPERATE :
1. Make sure that Remote Control switches are connected to the system.
2. Check that SPA Switch at Remote Control is in "POOL" position.
3. Check that CLEANER TIMER Dial in Power Center is programmed on.
4. Check cleaner pump circuit breaker at electrical subpanel.
5. Pool Cleaner pump may require servicing.
HEATER DOES NOT OPERATE :
1. Make sure that filter pump is on.
2. Check heater thermostat setting and pilot light (if applicable).
3. Check filter pressure. If filter is clogged, the heater may not be getting
sufficient water flow.
4. Heater may require servicing.
SPA WATER LEVEL DROPS :
1. Check that SPA SERVICE Switch in Power Center is in "AUTO" position.
3. Check that cables have not been unplugged from Valve Actuators.
4. A "check valve" in the system may be leaking. Refer to a qualified service
company.
SAVE THESE INSTRUCTIONS
P/N 9410938 Rev. A September 30, 2004
8
SWITCHING SYSTEM
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
1
CP-30
POOL-SPA
USER'S GUIDE