7 TROUBLESHOOTING
[Error message data table]
When a response message for a message request from the self-node is an abnormal response
message, the message data is stored in the error message data table within the FL.NET module.
The specification for the error message table is given below:
Total number of error
messages
Transmission source node
number
Received TCD
Error message word count
Error code data section
Note: If an abnormal response message is received when another abnormal response message is
already stored in the error message table, the total error message count is incremented (by one)
and the contents of the error message are overwritten by those of the newly received one.
Main module
Submodule
0xD41380
0xDC1380
0xD41382
0xDC1382
0xD41384
0xDC1384
0xD41386
0xDC1386
0xD41388
0xDC1388
0xD41788
0xDC1788
Item
15
2
Total number of error messages
Transmission source node number
Received TCD
Error message word count (in bytes)
Error code data section
Total number of abnormal response messages received
after power supply ON.
Node number of the source of transmission of an
abnormal response message
TCD number of an abnormal response message
Data section size (error code size) of an abnormal
response message. It is displayed in bytes.
This area is used to store the data section (error code) of
an abnormal response message. It can hold up to 1024
bytes of data.