1. Place the Cycle
Control Knob in the "OFF"
position.
2. Remove the two thumb screws and slide the
ice cutter grid forward,
out of the two slots near
the water pan.
3. Unplug the electrical
harness.
CAUTION:
Any ice on the grid should
be melted
under running
warm water.
grid may stretch
and damage
grid wires.
4. Remove
all ice from the storage
bin and the
freezing
plate.
5. Drain the water pan by removing
the drain
plug and then replace
the plug.
*Accepted
by the National
Sanltatlon
Foundation
6. Pour YZ gallon
(1.9 L) of hot tap water into the
water pan and turn the Cycle
Control Knob to
"CLEAN:' This warms up the system to mal
cleaning
solution more effective.
Let circulate
for five minutes. While tap water is circulating,
prepare
cleaning
solution. Mix:
6 oz. (170 g) powdered
citric,
or phosphoric
acid into
Yz gallon
(1.9 L) hot water
(Citric and phosphoric
acid crystals are
available
from many pharmacies
or scientific
supply
houses.)
Commercial
ice machine
cleaners
(liquid)
are
also available
from your dealer
or refrigeration
parts supply
stores. Mix according
to instruc-
tions on label (total quantity
YZ gallon
[I.9 L]).
7. Turn Cycle
Control Knob to "OFF" and drain
the water pan. (See step 5.)
8. Turn the Cycle
Control Knob to "CLEAN" and
slowly pour the hot cleaning
solution into the
water pan. (If solution foams while pouring.
wait
until foaming
stops.] Then add the balance
of
the solution.
Allow solution to circulate
until the scale has
dissolved
(15 to 20 minutes). Severe scale build-
up may require
repeated
cleaning
with a fresh
quantity
of cleaning
solution.
To clean
scale off the side flanges
of the freez-
ing plate, use rubber
gloves and scrub with a
plastic scrubber
or non-soap
filled stainless
steel pad dipped
in cleaning
solution.
9. Keep rubber gloves on to drain the cleaning
solution. Turn the Cycle
Control
Knob to "OFF"
and drain the water pan. (See step 5.)
10. Replace
the plug and add YZ gallon
(1.9 L)
of fresh water, Set Cycle
Control Knob on
"CLEAN:' circulate
five minutes and drain.
Repeat
rinsing process.

Advertisement