Description
3.3 Technical features and system requirements for built-in motors
Motor with full protection, integrated into the system via SMC20
1)
1
11 SINAMICS S120 Motor Modules, Booksize
12 Tripping unit
2
3.3.4

Version and operating modes of the motor in the synchronous version

1FE2 motors of shaft height 180 (1FE218☐) consist of two winding systems, i.e. each motor
has six connecting cables (three connecting cables for each winding system).
Both partial windings are galvanically separated and only weakly coupled magnetically.
This means the motors can be operated in two different ways.
Option 1: Connection of the two windings to one (large) power section and the "classic"
operation of the motor on a CU/NCU.
38
Article numbers for prefabricated
MOTION-CONNECT signal cables, M23
connector size
Control cabinet
format, DRIVE CLiQ communication via
SMC20
1FE2 built-in motor
Article numbers for prefabricated
2)
MOTION-CONNECT power cables
≲ 25 m in the case of star-delta changeover in
the control cabinet
21 Incremental encoder sin/cos 1 Vpp or EnDat
2.1 absolute encoder
22 1FE2 winding, connection via terminal box
3
Signal cable for encoder and temperature
sensor,
17-pin M23 round connector
4
Signal cable for PTC via tripping unit
SIMOTICS M-1FE2 built-in motors