National Instruments MXI-Express Gen-3 x16 User Manual page 34

Multisystem extension interface for pci express, compactpci express, and pxi express bus systems
Table of Contents

Advertisement

Caution
device is completely dry and free from contaminants before returning it to service.
Shock and Vibration
Operating shock
Random vibration
Operating
Nonoperating
Safety
This product is designed to meet the requirements of the following standards of safety for
information technology equipment:
IEC 61010-1, EN 61010-1
CAN/CSA-C22.2 No. 61010-1
Note
For UL and other safety certifications, refer to the product label or the
Product Certification
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment
for measurement, control, and laboratory use:
EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
EN 55011 (CISPR 11): Group 1, Class A emissions
AS/NZS CISPR 11: Group 1, Class A emissions
FCC 47 CFR Part 15B: Class A emissions
ICES-001: Class A emissions
Note
In the United States (per FCC 47 CFR), Class A equipment is intended for
use in commercial, light-industrial, and heavy-industrial locations. In Europe,
Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended
for use only in heavy-industrial locations.
Note
Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical
equipment that does not intentionally generate radio frequency energy for the
treatment of material or inspection/analysis purposes.
Note
For EMC declarations and certifications, and additional information, refer to
the Online Product Certification section.
34 | ni.com | MXI-Express Gen-3 x16 User Manual
Clean the PXIe-8394 with a soft nonmetallic brush. Make sure that the
section.
30 g peak, half-sine, 11 ms pulse (Tested in
accordance with IEC-60068-2-27. Meets MIL-
PRF-28800F Class 2 limits.)
5 Hz to 500 Hz, 0.3 g
5 Hz to 500 Hz, 2.4 g
with IEC-60068-2-64. Nonoperating test
profile exceeds the requirements of MIL-
PRF-28800F, Class 3.)
rms
(Tested in accordance
rms
Online

Advertisement

Table of Contents
loading

Table of Contents