'VII. SYSTEM CHECKOUT
Perform these tests after the wiring and option selections desired in
the previous sections have been completed.
1. Install tha PROM (No. 691 or No. 696) into its socket (see Diagram
5) after makmg certain that there is no power going to the system.
Take care to align the PROM orientation marks. Install the PROM
using the No. 69.2 Insertion Tool.
2. Connect the toiephone line
and
bandseta via a No. 626 Direct
Conneot Cord (See Diagram 5).
3. Connect the battery by connecting me insulated FAST-ON
4
terminals al the end of the black and red wires coming from the
circuit board to the male push-on lerminals on the battery. Fallure
to observe polmity wlil cause
l
iaga cylindrical light bulb
(boated to the iett 01 ttw point where the black and rod rlrer
am rltached
to the &cull
board) to be lb. Failure to correct the
polarity wiring error wlthtn a lewminutea will cause damage to
the C-COM. This light bulb will also be dimly II1 when the
battery voltage fait; to a iow kvel, with the intensity Incmaslng
as the voltage falls more.
Plug the tmnstormer Into a 11OVAC outtet that is ON 24 hours
a day. The POWER LED will light on the Remote Keypad.
5. Observe the READY LED on the Remote Keyped. I1 will light
(GREEN) if the protective loops are properly wired and all contacts
are properly set
6. With no atarm or trouble being Indicated. Do the following and
observe the response:
a. Open oath 01 the closed &cult bugiary aones momentarliy,
one at a time. The appropriate zone LED should ltght on the
keypad while the zone is open (and the ZONE DISPLAY key is
depressed).
b. Short each 01 the.open ctrwlt burglary zones momentarily,
at a time. The appropriate zone LED should light on the
keypad while the zone is shorted (and the ZONE DISPLAY key is
depressed).
7. If the llm zone has been set up, do the following:
a. Obsewe the TROUBLE LED on any Remote Keypad. It should
be Off if the protective loop and detector power circuits are
properly wired.
b. Disconnect one wlm 01 the Hm zone. The TROUBLE LED on
the keypad should light. A tone should be heard from the Remote
Keypad once every 15 seconds.
c. Sltence the troubie sounding by pressing the CMND and
TEST/RESET keys on the keypad. The sound should stop but the
visual LED indicelion should continue, but as a flashing
indication.
d. Reconnect the llm aone
wim.
The visual fire trouble indication
should go out.
e. Short the fire zone for 3 seconds. A fire alarm should be
triggered, accompanied by a pulsed bell output.
Silence the alarm by pressing the CMND and the TEST/RESEI keys
on the keypad.
NOTEr The battery may not be fully charged. II this test is tried with
a low battery there will not be enough power to ring bells
or opomte simns. Let the battery charge (transformer
plugged in) for at least one-hatf hour if the battery is low.
6. Test panic olrcults by momentarily shorting panic zone terminals,
by operating an external, zone connected panic switch, and by
depressing both of the EMERG keys on the keypad (if programmed).
If a panic zone is programmed for audible alarm, exterior siren or
bell should sound. If bells are used. a steady bell sound will be
produced. These conditions continue after the short is removed. A
message will be transmitted to the central station. Reset the system
by entering the security code at a keypad. Panic alarm reporting will
be re-enabled after a 1 minute delay.
If the zone is programmed for silent operatron. the above menttoned
sounds will not be heard.
9
a
shunt any purposety taulted BURGLARY Zone by first depressing
the CMND and BYPASS kevs to enter the bypass mode..The BYPASS
LED will flash to indicate th& this mode is in effect. Then press the
key corresponding to the number of the zone to be shunted. The
Zone LED will be on steady. Exit the bypass mode by depressing the
CMND key. The BYPASS LED will now be on steady. This zone may
nbw be faulted without causing an alarm.
10. Arm the system from a
keypad
and immediately follow the
security code entry by soauentlat doom&on
01 the CYND and
11
12
INSTANT keys. TheiNSTANT LED on the keypad should lioht,After
allowing for the exit delay to expire, any fault introduced in the
entry/exit zone will cause an immediate alarm. Disarm the system
and note that the INSTANT LED will go out.
Turn on the Chlme Mode by depression of the CMND key followed
by depression of the CHIME key during the disarmed state. Open and
close any contact in the entry/exit zone and a single tone will be
produced al any keypad for each fault announcing the entry of
someone. Remove the Chime Mode by depressing the CMND key
tollowed by depression the CHIME key.
Conduct a burgbry myatom test by depression of the CMND and
"4" keys during the disarmed state. The system is now in the Test
Mode.
In this mode, a momentary fault in any burglary zone will cause a
loud 'h second alarm sound from the exterior siren or bell.
13. All the tone contacts may now be oheoked by disturbing each
contact in each zone and listening for the short siren and/or bell
sound (whichever is used).
.
14. Remove tiw fe8t Mode by depression of any key to restore the
system to normal lunckoning.
15. DBconnoct AC power to the system. The POWER LED on the
keypad should rmmedrately flash but the system should remain
operable. After a number of hours 01 operation (depending upon
load), a low batlery report will be communicated to the central station.
Restore AC power to the system.
16. Arm the syrtem and rimubte kwving the pmmlses by
following the procedures in the OPERATION Section.
17. Slmutate antertng the pmmlrar and
dlurm
the sy8tem by
followrng the procedures given in the OPERATION Section.
VIII. OPERATION
AC POWER LED ON EACH REMOTE KEYPAD SHOULD BE LIT
STEADY AT ALL TIMES. If flashing, AC failure is indicated and the
system is operating on battery. Check plug-in transformer or for power
failure.
TO ARM BURGLARY SYSTEM:
1. Make aum the POWER LED is lit.
2. The READY LED on the remote keypad 8hauid be ilt to indicate that
all zones are properly closed.
it the READY LED h not lit, check the Burglary Zone I.D. Display on
the keypad (depress and hold ZONE DISPLAY key to get display). A
faulted zone indication denotes a fault which must be cleared or the
zone shunted prior to arming. Make sure that the exit door is dosed!
3. Dotormim II staying or teawng.
a.) II nmalnlng
on the premiaea
l
fler arming, first sequentially press
the CMND and STAY keys. Interior zone should now be turned OFF
and the STAY LED should be lit. Enter the security code and the rest
of the burolarv zones in the svstem should now be armed fentrvlexit
zone affer-exit delay timeout 1 denoted by the flashing of the ARM
LED). This is indicated at the keypads by one brief lone and the
steady lighting of the ARM LED.
b.) It k8vlng the pmmlses atter arming, just enter the security code.
All burglary zones shoufd now be armed (entry/exit zones after exit
delay timeout - denoted by the flashing of the ARM LED). This is
indicated at keypads by one brief tone and the steady lighting of the
ARM LED.
Depart before the exit delay period ends, via an entry/exit door
NOTE: Failure to arm is indicated by a failure to obtain the single
lone at the keypad and by failure to turn on the ARM LED. If
the failure to arm was because the wrong code was entered.
the situation IS indicated by 5-6 rapid beeps from the keypad.
TO DISARM BURGLARY SYSTEM:
1. When entertng the pmmtser, enter only
via
the entry/exit door. A
steady tone will be heard from keypads during the entry delay period.
it already wlthln pmmlse8, go directly to the nearest keypad
NDtE: If both the ARM and READY LEDs are flashing, it is an indication
of the memory of an alarm that took place previously. The user