C. BYSTBY OPTIONS
The system can be configured in a number of ways. This allows the
user
to
customize the system for his own particular needs. Before
actualty making the choices which affect how the system operates (See
Section V PROM Programming). it is important to understand the
options. The discussion that follows broadly divides those options into
two categories: control options and communicator options.
conlrofoPtlons
1. Entry Delay, Exit Deley
The entry delay is the time between entering the premises and when
the system must be disarmed to avoid activating an alarm. The exit
delay is Me time between aming the system and when the premises
must be.extted to avoid activating an alarm. The entry and exit delays
may be independently PROM selected to be between 0 and 120
seconds in 8 second increments (45 seconds maximum for entry
delay and 88 seconds maximum tar exit delay when used in a
household burglary UL Standard 1023 Listed application).
2 Communkator
D&y
The system may be set up to delay the triggering of the
communicator for burglary alarms by 15 seconds. This feature may
be used to reduce false alans due to user errors. See
Communicator Options section for comments on open/close and
trouble reporl communicator delays.
3. Belwslron Theoul
Bell/Siren audible indication may be PROM selected to tast between
0 and 15 minutes in 1 minute increments (4 minutes minimum when
used in a household burglary UL Standard 1023 Listed application),
after which it "times out". The fire zone may be optionally selected to
have its alarms not time out, wherein manual shutdown would be
required to sikmce a fire alarm (for household fire UL Standard 985
Listed applications, the tie atann musl not time out).
4. Pallc zone opthwl
The system offers two panic zone types - silent panic and audible
panic A programmable zone may be configured as either type by
PROM selection.
5. Butglq
Zonn
Option
The system offers mme burglary zone types - entry/exit, partmeter
and interior. A programmable zone may be configured as any one of
these types by PROM selection.
The burglary zones may be configured for silent or audible alarm by
PROM selection for all of the burglary zones as a group (silent alarm
may not be selected when in a household burglary UL Standard
1023Listed application).
a soamy
code
This 4 dtgl code restricts the use of the system to only those who
know me code. Any digits, including repetitions. may be chosen.
There are mree such codes (not including the duress code descrtbed
below). One is PROM programmed at installation
and the other codes
era user changeable from a keypad at any time, using the master
code to enable the change.
7.DumaCode
The duress code is a
separate
security code. Its purpose is to allow
someone to initiate a silent panic condition but still give the
impression that the control is working normally. For example. if one
codeis1234~theduresscodeis1235,enteringl234willCa~
the system to disarm, but entering 1235 (assuming one is in a
hostage sttuation) will cause the system to disarm, but will also
trigger the communicator to aand a sitent panic message.
H used with the No. 691 PROM (see Sectiin V PROM PRO-
GRAMMING), a Zone 2 report is transmttted. If used WiM the No.
696 PROM, a Zone 7 mport is transmitted.
NOTEr It the user of the system inadvertently programs a duress code
that is the samaas the master code, the duress Silent panic
capability is suppressed to avoid the transmtsaion of tatse
alarms to me central etarm monitoring service.
abd~z0n0(wllatlng
individual zone ahuntii
allows a uaar to arm the system even
though certain burg&y zonas are fautted or will ba later faulted and
abctuktn't cause anatarm. Such zones can be Shunted white the
system is disarmad by depressing the CMND and BYPASS keys and
by then totlowing wtth the number of the zone to be shunted. Nate
#tat 24 hr zones carm~l be shunted.
RparlJpAtlll
The system may be PROM selected to power up in either the armed
or disarmed state atter sn extended power outage during which AC
power is test and the back-up battery is depleted. Upon restoration Of
AC power, the keypad sounder will sound a steady low level tone for
1 minute. During this 1 minute period, the user may abort the power
up am'! Sequence by pressing any key. At the end of this 1 minute
period, the system will shunt any burglary zones which are faulted
and will then arm itself. Bypass and closing reports are transmitted (ii
PROM enabled) to the central station, Code 9 will appear as the user
number in extended closing reports to indicate to the central station
that the system armed itself.
*mmunlator
Otiionr:
1. Communlutor
Enablea
The system may be PROM programmed to transmit any combination
of the following messages:
0) openmoee
Repotls
A closing report, 1 PROM enabled. will be sent whenever the
system is completely armed or just parimeter armed (i.e.: STAY
mode operation) The communicator delay for closing reports is
fiied at 15 seconds. The system may be disarmed during this
period without either closing or opening reports being sent to the
central station,
b) Extended Report8
If PROM enabled. the system will report additional information to
the central station. This information includes:
(1) Zone identification associated with transmission of a Restore.
(2) User identification at the time of dosing and opening.
Use of: secondary security code al is identified by "1"
secondary
security code #2 is identified by "2"
master security code is identified by "4"
NOTE: Code 9 appears as me user u when the system powers up
armed after an extended power outage.
c) Plre Troubh Rqmrb
The system will transmit a troubte report. if PROM enabled.
whenever a trouble condition is sensed in the fire zone and has
been present for at least one minute. When the troubte condition
has restored, and remained restored for l-2 minutes. a restore
message will be sent.
d) Cancel Ropori
If PROM enabled, the cancel report will be sent if a burglary alarm
is turned off (cancelted) before the betl/siren times out. If opening
reporting is enabted. the cancel report will be followed by an
opening report Cancel reporting
does
not apply for fire or panic
alarms.
l
) Duras Roporl
A duress report, if PROM enabled, will be sent whenever the
system is armed or disarmed using secondary security code ff3.
This system code is reserved for duress alarm activation.
NOTEr Duress reports are not accompanied by either opening or
closing reports.
f) Teat ReporI
As delivered.the system has the capability to transmit a manually
initiated (CMND+ "5" keys) Test report to the central station if the
reporting code for Test is PROM programmed. It it is desired to
send the Test report automatically, as a means to verify that the
communications link between the protected premises and me
central station is operative, a second PROM option is offered - 24
hour test. With this opt& selected. the system tniiites a Test
message call every 24 hours, starting 12 hours after the time of
instatlation.
This option goes into effect at tnstaltabon ttt
tf PROM enabled. If
any other transmission is sent by the system during the ensuing
24 hour period (e.g. open and closing reports), then the test
message is not sent.
2Roportto
m
(Rummy) Phone Numkr
Abe
The system altows for the various communicator reports to be
dii
between two central stations (or two receivers). This is done
in aome sttuations where, for example, all alarms may be routed to a
primary alarm receiver white non-critical items, such as troubtes or
2