baud baud rate,from 300-921600
data data bit 8
stop stop bit 1、2
parity ODD(odd)、EVEN(even)、NONE(none)
flowctrl flow control bit NFC(without flow control)、FC(with flow control)
Example: AT+UART=9600,8,1,NONE,NFC<CR>

5.5.13 AT+VER inquire module version info.

Function:inquire module version info.
Format:inquire
Transmit: AT+VER<CR>
Return: <CR><LF>+OK=<ver><CR><LF>
Parameter:
ver version number
Example:AT+VER<CR>

6 FAQ

6.1 Module is easy to damage

Please check the power supply, ensure it is incorrect range, otherwise,module will be damaged.
Please check the stability of power supply, the voltage cannot fluctuate too much.
Please make sure antistatic measure are taken when installing and using.
Please ensure the humidity is within limited range, some parts are sensitive to humidity.
Please avoid using modules under too high or too low temperature.

6.2 Unable to successfully set the command

Please check if the instruction format is correct.
Please check the flashing frequency of the indicator light. When the command is configured, the indicator blinks at
5Hz
Please check the mode used by the instruction.

6.3 Unable to use after parameter is changed

Please check if the serial port baud rate and CAN baud rate are set correctly.
Please check if the data format is in compliance.
Please check if the computer serial port is halted.
Please read the instruction manual carefully.