INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE MODEL FC FACTORY BUILT INSULATED CHIMNEY LISTED ® CAN/ULC-S604, CAN/ULC-S610 A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS CHIMNEY BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
FIGURE 1 2 ft. (600mm) 3 ft. (900mm) Your SuperVent/SuperPro Model FC chimney is intended as a min. component for specific listed factory built fireplaces and for connection to liquid fuel or gas fired residential type appliances and 2 ft.
In some application, the is enclosed immediately below the roof. crimped end will need to be removed as per fuel requirements and - Suitable lengths of Chimney (Model FC). The chimney diameter local installation codes. should be sized to suit the appliance.
Lock- ing bands must be used at all chimney joints. - Suitable lengths of chimney (Model FC). The chimney diameter should be sized to suit the appliance. Never install an elbow in a joist area. Chimney sections must pass vertically through framed joist areas.
Page 8
- Cathedral Ceiling Support: JSC CCS. Support Plate - Roof Flashing Assembly: JSC AAF, JSC AF2 - required when the chimney penetrates a roof. - Suitable lengths of chimney ( Model FC). The chimney diameter Female Coupler (Down) should be sized to suit the appliance.
The bottom chimney length(s) should protrude into the living space Slide the Roof Support down over the chimney section until its so that proper clearances are maintained on the stove pipe connec- brackets rest on the roof or floor. Tighten the collar around the tor.
Rubber Boot Flashing Kit URBFK1 URBFK1 CHEMICALLY TREATED WOOD, ETC.. Storm Collar JSC*SC JSC*SC Universal Shielding Insulation JUSI JUSI * Specify chimney size Model SuperVent(FC) and SuperPro (SPR) chimneys and components are interchangeable with one another. Both are listed to CAN/ULC-S604 and CAN/ULC-S610.
CHART 1 - OFFSET CHIMNEY INSTALLATION It may be necessary to offset the chimney in order to clear a joist or an obstacle. The three (3) charts below will assist you in selecting the proper combination of elbow angle and chimney length(s) that will provide the necessary degree of offset within an available height. OFFSET CHART 1.
CHART 3 - Connector Pipe Clearance below Cathedral Support 1. Identify the type of connector pipe you will be installing, single wall (requires 18" clearance to combustibles) or Selkirk's Double Wall Stove Pipe (model DSP) which requires 6" clearance to combustibles.