F I R E P L A C E M o d e l 6 4 0 / ZC40 Installation Instructions & User's Guide LISTED TO ULC S610-M87 & UL127(May 2001) ® Selkirk Canadian Operations 375 Green Road 1400 California Avenue Stoney Creek, Ontario. Brockville, Ontario. L8E 4A5 K6V 5V3 www.supervent.ca...
5. Inspect your ladder for condition. Make certain that all points of the base always rest on a level, firm surface. 14. Supervent's (Model SC, JM, & ALT) and Selkirk's Metalbestos (Model SS, & CF) 6" & 7" Insulated chimneys have 6.
of any of the required parts or materials may seriously impair the safety of your installation, and void the manufacturers warranty and the conditions of approval. FIREPLACE LOCATION: 1. Select fireplace location taking into consideration such things as size of room, traffic patterns, location of doors and windows, chimney location, to minimize any offsets, and required clearance to side walls.
50mm(2") and exterior joints. 6. Figures 6 - 9 shows the four basic types of installations most likely to be encountered when installing a Model 640/ZC40 fireplace system. RADIATION / DUST SHIELD 50mm(2") All joist areas must be fully framed to accept a Radiation / 50mm(2")
ATTIC INSULATION SHIELD / FIRESTOP SPACER FIRESTOP ENCLOSURE RADIATION (Selkirk Model SS Plus & CF) SHIELD LIVING SPACE This shield has three main components: the Attic Insulation FRAMING JOIST Shield (upper box), the Support Angles and the Joist Shield. (ALL FOUR SIDES)
FIGURE 13c ELBOW CHASE PLUG INSTALLATION SUPPORT (Selkirk and Supervent) 1. The Chase Plug is designed and manufactured to maintain FIGURE 15 the thermal envelope of your house. The Chase Plug must be installed from the bottom side of a 13"(330mm) square OFFSET SUPPORTS opening using 8 -2"(6d) spiral nails.
FIGURE 17 FIGURE 20 ROOF BRACKET CHIMNEY 1. Place Adapter over opening at top of your Model 640/ZC40 PLATE Fireplace. 2. Twist the Adapter into the opening ensuring the adapter is completely in place until the bottom edge of the adapter bottoms out on the top of the bead edge inside the fireplace flue.
EXTERIOR CHIMNEY INSTALLATIONS CF ADAPTER/chimney INSTALLATION (Model CF) (Models SS Plus, SC, & SPR) 1. Place adapter on fireplace, see Chimney Adapter Installation. 1. On a through the wall installation as shown in figures 6c & 9c, an intermediate wall support is required 2.
3. Wall bands must then be installed at 2.4m(8ft.) intervals 8. If the chimney extends more than 2m(6ft.) above the roof above the intermediate wall support. deck, then roof guys are required. Model JURGK-1 is suitable for this application. The draw band must be 4.
3. Select the side of the fireplace that the gas conduit is to be WARNING: THE OUTSIDE AIR KIT VENT MUST VENT run through, and remove the refractory from that side by TO THE OUTSIDE ONLY. DO NOT INSTALL THE removing the refractory clip.
NEVER OBSTRUCT OR MODIFY THE AIR DRYWALL INLET/OUTLET GRILLES IN ANY MANNER LINTEL TRIM CLIP OPERATING AND MAINTENANCE OF YOUR MODEL 640/ZC40 FIREPLACE & FIRING THE FIREPLACE BRICK OR NON- COMBUSTIBLE COMBUSTIBLE MATERIAL 1. Your fireplace has been designed to produce best results WALL by using aged dry wood.
OF ONE similar liquids to start or ‘freshen’ a fire in the Model 640/ZC40 fireplace. Any such liquids should be kept well 1. If a fire has got out of control in your fireplace or you away from the fireplace.
Page 17
3. Inspect the glass doors for signs of cracks or breaks on a regular basis, and if found, extinguish the fire and replace the pane of glass. 4. Never slam the fireplace doors as a protruding object (ie. log) may hit the glass and cause breakage. 5.
APPENDIX A.1 APPENDIX A.1 Selkirk Canadian Operations Model 640 / ZC40 Fireplace Installation Instructions for Outside Air Kit Items included in kit: 1) Air Valve Assembly 2) 3" Dryer Hood Assembly 3) 10' Flexible Ducting 4) Air Duct Clamps (2)
Page 19
APPENDIX A.2 APPENDIX A.2 INSTALLING AN OUTSIDE AIR KIT IN A CHASE: 1. If the chase is framed first, a minimum width of 1197mm (47-1/8") is required. A minimum width of 1146mm (45-1/8") can be used if the chase is to be framed later. 2.
APPENDIX C Selkirk Canadian Operations Model 640 / ZC40 Fireplace Installation Instructions for Cabinet Doors The Cabinet Door Kit Includes: Right Door Item Description 450mm Glass (17-23/32") Door Latch Assembly 430mm Pivots Left Door (16-15/16") Latch Pads (1/4") Pivot Pads...
APPENDIX D-1 Selkirk Canadian Operations Model 640 / ZC40 Fireplace Installation Instructions for Trim Kit INCLUDED IN KIT: (4) KEPS NUTS TOP TRIM (4) BOLTS (6) BLACK SCREWS AND/OR BRASS SCREWS LEFT TRIM UPPER DOOR TRIM RIGHT TRIM LOWER DOOR TRIM...
Page 23
APPENDIX D-2 STEP #4 Assemble the sides to the top using the nuts and bolts provided. Two (2) per side. Note: The side trim pieces are left and right and are not interchangeable. TOP TRIM REAR VIEW SIDE TRIM SIDE TRIM ASSEMBLY STEP #5 Fasten the screws (4) provided into the pre-punched holes of the inside edge of the fireplace, 2 per side.
ODEL IREPLACE SUBJECT TO THE CONDITIONS OUTLINED BELOW LIMITED LIFETIME WARRANTY: Selkirk Canadian Operations, (" ", " ", " ") warrants that each fireplace to be free from defects in material and workmanship under normal use and service for as long as the original consumer owns the system. For products installed after August 1, 2001, for a period of Ten (10) years from original installation, we will provide replacement product with a similar or like quality of avail- able product, free of charge excluding any installation costs.