ZERO CLEARANCE WOOD BURNING
Installation Instructions
®
Selkirk Canadian Operations
375 Green Road
Stoney Creek, Ontario.
L8E 4A5
www.supervent.ca
R M 8 8 0 0 7 2 L T
F I R E P L A C E
M o d e l 6 4 0 / ZC40
& User's Guide
LISTED TO ULC S610-M87 & UL127(May 2001)
1400 California Avenue
Brockville, Ontario.
K6V 5V3
www.selkirkcanada.com

Advertisement

Table of Contents
loading

Summary of Contents for Selkirk 640/ZC40

  • Page 1 F I R E P L A C E M o d e l 6 4 0 / ZC40 Installation Instructions & User's Guide LISTED TO ULC S610-M87 & UL127(May 2001) ® Selkirk Canadian Operations 375 Green Road 1400 California Avenue Stoney Creek, Ontario. Brockville, Ontario. L8E 4A5 K6V 5V3 www.supervent.ca...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY TIPS BEFORE YOU START BASIC INSTRUCTION GUIDELINES FOR FIREPLACE AND CHIMNEY INSTALLATION IMPORTANT INSTALLATION PRECAUTIONS FIREPLACE LOCATION FIREPLACE AND HEARTH EXTENSION INSTALLATION CHIMNEY FRAMING DETAILS CHIMNEY INSTALLATION INSTRUCTIONS RADIATION / DUST SHIELD MODELS SUPERCHIMNEY / SUPERPRO CHIMNEY INSTALLATIONS MODELS SUPERCHIMNEY 2100 / SUPERPRO 2100 CHIMNEY INSTALLATIONS MODEL CF CHIMNEY INSTALLATION MODEL SS PLUS CHIMNEY INSTALLATION...
  • Page 3: Safety Tips Before You Start

    5. Inspect your ladder for condition. Make certain that all points of the base always rest on a level, firm surface. 14. Supervent's (Model SC, JM, & ALT) and Selkirk's Metalbestos (Model SS, & CF) 6" & 7" Insulated chimneys have 6.
  • Page 4: Fireplace Location

    of any of the required parts or materials may seriously impair the safety of your installation, and void the manufacturers warranty and the conditions of approval. FIREPLACE LOCATION: 1. Select fireplace location taking into consideration such things as size of room, traffic patterns, location of doors and windows, chimney location, to minimize any offsets, and required clearance to side walls.
  • Page 5: Chimney Framing Details

    50mm(2") and exterior joints. 6. Figures 6 - 9 shows the four basic types of installations most likely to be encountered when installing a Model 640/ZC40 fireplace system. RADIATION / DUST SHIELD 50mm(2") All joist areas must be fully framed to accept a Radiation / 50mm(2")
  • Page 6: Models Superchimney / Superpro Chimney Installations

    MODELS SUPERCHIMNEY MAX / SUPERPRO CHIMNEYS VENTILATED ROOF STORM FLASHING COLLAR RAFTER RADIATION SHIELD ENCLOSED ATTIC SPACE INSULATION WALL BAND FIRESTOP ENCLOSED RADIATION LIVING LOCKING SHIELD SPACE BAND INSULATION INTERMEDIATE WALL OFFSET SUPPORT 30° WALL SUPPORT FIRESTOP RADIATION SHIELD PLUG 15/30/45°...
  • Page 7: Models Superchimney 2100 / Superpro 2100 Chimney Installations

    MODELS SUPERCHIMNEY 2100 MAX MODELCF SENTINEL SUPERPRO 2100 VENTILATED STORM ROOF VENTILATED STORM COLLAR FLASHING ROOF COLLAR FLASHING RAFTER RAFTER ENCLOSED RADIATION RADIATION ENCLOSED ATTIC SHIELD SHIELD ATTIC SPACE SPACE INSULATION INSULATION ENCLOSED ATTIC INSULATION ENCLOSED LIVING SHIELD INTERMEDIATE LIVING SPACE JOIST SPACE...
  • Page 8: Model Ss Plus Chimney Installation

    MODEL SS PLUS CHIMNEY STORM ROOF COLLAR FLASHING RAFTER RADIATION SHIELD ENCLOSED ATTIC SPACE INSULATION WALL BANDS RADIATION / ENCLOSED DUST SHIELD LIVING LOCKING SPACE BANDS INSULATION INTERMEDIATE WALL OFFSET 30° WALL SUPPORT SUPPORT RADIATION / PLUG DUST SHIELD 15/30/45° 7ft.
  • Page 9: Attic Insulation Shield / Firestop Spacer

    ATTIC INSULATION SHIELD / FIRESTOP SPACER FIRESTOP ENCLOSURE RADIATION (Selkirk Model SS Plus & CF) SHIELD LIVING SPACE This shield has three main components: the Attic Insulation FRAMING JOIST Shield (upper box), the Support Angles and the Joist Shield. (ALL FOUR SIDES)
  • Page 10: Chase Plug Installation

    FIGURE 13c ELBOW CHASE PLUG INSTALLATION SUPPORT (Selkirk and Supervent) 1. The Chase Plug is designed and manufactured to maintain FIGURE 15 the thermal envelope of your house. The Chase Plug must be installed from the bottom side of a 13"(330mm) square OFFSET SUPPORTS opening using 8 -2"(6d) spiral nails.
  • Page 11: Cf Roof Support

    FIGURE 17 FIGURE 20 ROOF BRACKET CHIMNEY 1. Place Adapter over opening at top of your Model 640/ZC40 PLATE Fireplace. 2. Twist the Adapter into the opening ensuring the adapter is completely in place until the bottom edge of the adapter bottoms out on the top of the bead edge inside the fireplace flue.
  • Page 12: Cf Adapter/Chimney Installation

    EXTERIOR CHIMNEY INSTALLATIONS CF ADAPTER/chimney INSTALLATION (Model CF) (Models SS Plus, SC, & SPR) 1. Place adapter on fireplace, see Chimney Adapter Installation. 1. On a through the wall installation as shown in figures 6c & 9c, an intermediate wall support is required 2.
  • Page 13: Roof Flashing Installation

    3. Wall bands must then be installed at 2.4m(8ft.) intervals 8. If the chimney extends more than 2m(6ft.) above the roof above the intermediate wall support. deck, then roof guys are required. Model JURGK-1 is suitable for this application. The draw band must be 4.
  • Page 14: Fan Kit Installation

    3. Select the side of the fireplace that the gas conduit is to be WARNING: THE OUTSIDE AIR KIT VENT MUST VENT run through, and remove the refractory from that side by TO THE OUTSIDE ONLY. DO NOT INSTALL THE removing the refractory clip.
  • Page 15: Enclosing The Fireplace

    NEVER OBSTRUCT OR MODIFY THE AIR DRYWALL INLET/OUTLET GRILLES IN ANY MANNER LINTEL TRIM CLIP OPERATING AND MAINTENANCE OF YOUR MODEL 640/ZC40 FIREPLACE & FIRING THE FIREPLACE BRICK OR NON- COMBUSTIBLE COMBUSTIBLE MATERIAL 1. Your fireplace has been designed to produce best results WALL by using aged dry wood.
  • Page 16: Operating The Fireplace

    OF ONE similar liquids to start or ‘freshen’ a fire in the Model 640/ZC40 fireplace. Any such liquids should be kept well 1. If a fire has got out of control in your fireplace or you away from the fireplace.
  • Page 17 3. Inspect the glass doors for signs of cracks or breaks on a regular basis, and if found, extinguish the fire and replace the pane of glass. 4. Never slam the fireplace doors as a protruding object (ie. log) may hit the glass and cause breakage. 5.
  • Page 18: Installation Instructions

    APPENDIX A.1 APPENDIX A.1 Selkirk Canadian Operations Model 640 / ZC40 Fireplace Installation Instructions for Outside Air Kit Items included in kit: 1) Air Valve Assembly 2) 3" Dryer Hood Assembly 3) 10' Flexible Ducting 4) Air Duct Clamps (2)
  • Page 19 APPENDIX A.2 APPENDIX A.2 INSTALLING AN OUTSIDE AIR KIT IN A CHASE: 1. If the chase is framed first, a minimum width of 1197mm (47-1/8") is required. A minimum width of 1146mm (45-1/8") can be used if the chase is to be framed later. 2.
  • Page 20: Appendix B (Blower Kit)

    APPENDIX B Selkirk Canadian Operations Model 640 / ZC40 Fireplace Installation Instructions for Direct Blower Kit Items included in kit: 1) Blower assembly 3) Electrical junction box cover 5) Variable switch 2) Electrical junction box 4) Blower deflector 6) 30" three prong plug...
  • Page 21: Appendix C (Cabinet Doors)

    APPENDIX C Selkirk Canadian Operations Model 640 / ZC40 Fireplace Installation Instructions for Cabinet Doors The Cabinet Door Kit Includes: Right Door Item Description 450mm Glass (17-23/32") Door Latch Assembly 430mm Pivots Left Door (16-15/16") Latch Pads (1/4") Pivot Pads...
  • Page 22: Appendix D (Trim Kit)

    APPENDIX D-1 Selkirk Canadian Operations Model 640 / ZC40 Fireplace Installation Instructions for Trim Kit INCLUDED IN KIT: (4) KEPS NUTS TOP TRIM (4) BOLTS (6) BLACK SCREWS AND/OR BRASS SCREWS LEFT TRIM UPPER DOOR TRIM RIGHT TRIM LOWER DOOR TRIM...
  • Page 23 APPENDIX D-2 STEP #4 Assemble the sides to the top using the nuts and bolts provided. Two (2) per side. Note: The side trim pieces are left and right and are not interchangeable. TOP TRIM REAR VIEW SIDE TRIM SIDE TRIM ASSEMBLY STEP #5 Fasten the screws (4) provided into the pre-punched holes of the inside edge of the fireplace, 2 per side.
  • Page 24: Replacement Parts List

    REPLACEMENT PARTS LIST 1. Hearth Refractory 2. Side Refractory (2) 3. Rear Refractory 4. Refractory Clips (3) 5. Hearth Front 6. Top Door Frame 7. Bottom Door Frame 8. Top Grille 9. Bottom Grille 10. Damper Blade 11. Damper Shaft 12.
  • Page 25: Warranty

    ODEL IREPLACE SUBJECT TO THE CONDITIONS OUTLINED BELOW LIMITED LIFETIME WARRANTY: Selkirk Canadian Operations, (" ", " ", " ") warrants that each fireplace to be free from defects in material and workmanship under normal use and service for as long as the original consumer owns the system. For products installed after August 1, 2001, for a period of Ten (10) years from original installation, we will provide replacement product with a similar or like quality of avail- able product, free of charge excluding any installation costs.