INSTALLER SETTING
90
DHW time setting
Determine following time duration : operation time of DHW tank heating, stop time of DHW tank
heating, and delay time of DHW tank heater operating.
- Active time : This time duration defines how long time DHW tank heating can be continued.
- Stop time : This time duration defines how long time DHW tank heating can be stopped. It is
also regarded as time gap between DHW tank heating cycle.
- Boost heater delay time : This time duration defines how long time DHW tank heater will not be
turned on in DHW heating operation.
- Example of timing chart :
1
DHW tank
0
heating is enabled
1
DHW tank heater
0
is enabled
S
1
DHW tank
heating operation
0
1
DHW tank
B
heater operation
0
❈
1=active / 0=not active
❈
A = Active time
❈
S = Stop time
❈
B = Boost heater delay time
A
S
S
B
Time
OK
Use Heating Tank Heater
It is the function to change the setting value of heating tank heater operation such as use / non-
use and heater delay time of heating tank heater
• Change setting values using [<,>(left/right)] button.
Value1
Use/Not Use
Not use
Use disinfect
Use
Heater / Cycle
INSTALLER SETTING
OK
Value2
Value3
Priority
Delay time
-
-
-
-
Cycle
10, 20, 30, 40, 50, 60,
90, 120, 1440