4. Product Parts and Functions
5. MENU Details
5-1. Measure Menu
When power is on, Measure Menu is displayed as the initial menu screen. Select the Type and
Cable and press Run button for less than 3 seconds to display 1 time measured value and save it
to LIST. Press Run button for over 3 seconds to display 8 times measured value and save them to
LIST.
The cable length of BNC and RJ45 is saved to LIST in Cable Length menu, and loop resistance
value is saved to LIST in Loop Resistance menu.
• 1 Type: Control direction key ◀▶ to select among BNC, RJ45 and Loop Resistance Type.
• 2 Cable: Control direction key ◀▶ to select LOAD DATA of BNC, RJ45 Type Cable.
• 3 Menu: Press Enter key to move to sub-menu according to the selected Type.
※ In '2 Cable' menu, 'USER' cannot be modified or deleted because it is a LOAD DATA that the
calibrated value is initialized.
■ BNC Type (Coaxial Cable) Setting and Measurement
①. RJ-45: UTP cable connection port.
②. Power Input: Built-in battery charging port. USB Cable (DC 5V/500mA)
③. BNC: Coaxial cable connection port.
④. Display: 1.5 inch OLED
⑤. Power Button: Press for more than 2 sec. to turn ON/OFF.
⑥. Direction Switch: Switch to set menu.
To set menu, control with ▲▼, ◀▶ direction switch
To activate Enter Key, press the direction switch.
⑦. Run Button: Button to measure cable.
Used for cable measurement.
When Green LED is on, press the switch to start measurement.
⑧. Charge Status LED
●Red - Charging. ●Green – Charging done.
Press Run(Green LED ON) button to measure.