Genie CT10 User Manual page 10

Hide thumbs Also See for CT10:
Table of Contents

Advertisement

* Cable length measurement or LOOP resistance value may vary depending on cable standard or
specifications. Make sure to proceed Calibration (refer to 5-3) when applying additional is
required additional to built-in Load Data.
5-6. Loop Resistance
• Available in BNC Mode. Measure loop resistance of coaxial cable.
※ When measuring, connect BNC to TB Connector to the cable end and set the switch to Loop.
• START: When set in menu, Green LED lights up on the Run button. Press the Run button to
measure the cable loop resistance.
• LIST: Press RUN button for less than 3 seconds to display 1 time measured value. Press RUN
button for over 3 seconds to display 8 times measured value. Press Enter key to return to the
previous menu.
Select Loop Resistance
• LIST Menu
: Measure coaxial cable loop resistance.
Select START
1 time measurement
(press Run button below 3 seconds)
- 10 -
Measure Loop Resistance
In case of OPEN
8 times measurement
(press Run button over 3 seconds)

Advertisement

Table of Contents
loading