General Technical Specifications - Salicru DC POWER-L Series User Manual

Thyristor-controlled charger rectifier 25.. 800 a
Hide thumbs Also See for DC POWER-L Series:
Table of Contents

Advertisement

11. Annexes.

11.1. General technical specifications.

INPUT
AC voltage (V)
Regulation range
Frequency (Hz)
Power factor
Performance 100% of load (%)
OUTPUT
Rated DC voltage (V)
Accuracy with batteries (%)
Float voltage
Quick charging voltage
Exceptional charging voltage
Ripple voltage without batteries
(%)
Ripple voltage with batteries (%)
Rectifier output current (A)
BATTERIES
Type
No. PbCa cells
Number of elements (NiCd)
Charge type
Battery charging current
Recharge time
Protection
Quick charging
Exceptional charging
Float voltage/ambient
temperature compensation
PROTECTION AND OPERATION ELEMENTS
Rectifier input
Auxiliary input for TSS
Batteries (in system cabinet)
Batteries (in external cabinet)
General output
Soft start
40
Single-phase 230 V AC
(3 wire: 1 phase + N + TT)
Three-phase 3x230 or 3x400 depending on
model (4 wire: 3 phases + TT)
± 15%. Outside this range, the
corresponding alarm is activated.
With input voltage of –20%, the rectifier
is blocked and the loads continue to be
powered from the batteries while backup
is available
50 / 60 ± 5% (47.5.. 52.5 / 57.. 63)
0.85 (with rated input, 100% load and
floating output voltage)
> 85
24
48
110
120
125
± 1
2.28 V/cell (PbCa) / 1.4.. 1.45 V/el. (NiCd)
2.5 V/cell (PbCa) / 1.5 V/el. (NiCd)
2.7 V/cell (PbCa) / 1.65 V/el. (NiCd)
< 3
< 1
25 / 50 / 75 / 100 / 150 / 200
PbCa (sealed or open) or NiCd
12
24
55
60
62
19
38..39 81..86 88..94 92..96 161.. 173
Constant I/U in accordance with
DIN 41773
0.1.. 0.3 C adjustable
Up to 80% in 4 hours (0.2 C)
Against overvoltage and undervoltage
Automatic according to established
conditions or forced manually via the
control panel
Forced manually via the control panel and
limited by conditions established for 365
days
Yes, customisable according to battery
specifications (mV / °C)
Circuit breaker
Circuit breaker
Fuses
Fuses
Disconnector
Yes
COMMUNICATION AND ALARMS
Slot
SNMP / Remote maintenance
DB9 connector (COM1)
DB9 connector (COM3)
Relay interface (RELAYS),
potential-free contacts
Compensation of battery voltage
according to temperature
Low electrolyte level (for open
type batteries)
GENERAL
Dielectric strength
Protection rating
Ventilation
220
Rectifier operating temperature
Rectifier storage temperature
Relative humidity
Maximum operating altitude
Acoustic noise at 1 metre
Colour
Structure, supports and
accessories
Battery trays
Weights (kg)
110
Dimensions (mm)
LCD DISPLAY
Screen map menus (Fig. 15)
LUMINESCENT INDICATIONS
LED optical on the control panel
with LCD display
STANDARDS
Safety
Electromagnetic compatibility
(EMC)
Marking
Quality and environmental
management
Certification company
(11)
Power degradation from +40ºC.
(12)
No batteries.
(13)
Power degradation from 1000 masl.
Table 7.
General specifications.
Yes, one pre-connected as standard
NIMBUS, optional
Optional
Optional
3 relays, expandable to 6. Optional.
By means of a sensor installed in the
battery set
Optional. By means of a sensor installed in
one of the batteries
2500 V AC for 1 minute
IP20
Natural convection
(11)
–10 ºC to +55 ºC
(12)
–20 ºC to +70 ºC
Up to 95% non-condensing
(13)
Up to 3,000 masl
< 49 dBA (average)
< 57 dBA (max. value)
Cabinet structure and covers painted in
RAL-7035
Pre-formed and galvanised sheet steel
Galvanised sheet steel
Depending on configuration, see Table 6
Depending on configuration, see Table 6
- Main
- Measurements
- Operations
- User Parameters
- Alarms
- Battery Settings
- Password (necessary to display 'Battery
Settings' menu
a) Correct output indication
b) Input fault indication
c) Urgent alarm indication
d) Non-urgent alarm indication
IEC/EN 61204-7, IEC/EN 60950-1
IEC/EN 61204-3
CE
ISO 9001 and ISO 14001
SGS
USER MANUAL