by loosening the M5 screws (11) and allowing the water to drain out of the housing.
EN
4. Disconnect the cables of the valves by disconnecting the plug connections.
5. Remove the entire electrical part (12), including the rotating part, from the housing. Handle
the loose parts carefully to prevent damage to the internal wiring. Grease the rubber
seal (13) and the rotating part with a maintenance product for silicone-based rubber
(recommendation: Molykote 111 compound). If the rubber seal (13) is damaged, it can
be removed and replaced by loosening the small screws (14). The rubber seal (13) can be
ordered from your distributor.
6. Please note the correct position of the seal rings when re-installing the parts.
7. You can restart the pump when all parts are re-installed into their original position. Check
the system for flow and leaks.
OPERATING ELEMENTS
LCD touch-screen display
Backwash (manual)
TECHNICAL SPECIFICATIONS
Dimensions
Inlet / outlet
Supply voltage
Max. power circulation pump
Max. power blower
Fuse
Automatic valves
IP certification
Max. head pressure after waste valve
Maximum flow
Maximum system pressure
WARRANTY TERMS
You made an excellent decision when you chose this product. The device has been carefully
assembled in compliance with all applicable safety regulations. To achieve the desired quality,
the supplier has only used high quality materials. The supplier guarantees the product against
defects in materials and workmanship for two years from the date of purchase. The bulb and
the quartz glass sleeve are excluded from warranty coverage. Warranty claims can only be
processed if the product is sent back postage paid and are accompanied by a valid proof
of purchase. Warranty repairs may only be carried out by the supplier. Warranty claims that
are the result of incorrect installation or operation will not be honoured. Defects caused by
poor maintenance are also excluded from warranty coverage. The supplier is not in any way
responsible for damage caused by misuse of the product. The supplier cannot be held liable
for consequential damage due to failure of the device. Claims related to transport damage will
only be accepted if the damage was established or confirmed upon delivery by the carrier or
postal service. Only then is it possible to submit a claim to the carrier or postal service.
| XCLEAR FLOW-MATIC MANUAL
14
650 x 450 x 450mm
63mm (with reducer for 50mm)
230V AC 50Hz/60Hz
2.000 VA
900 VA
12A slow bow
24V
IP 54
max . 3,0 m
25.000 l/h
1,5 Bar