Electrical Requirements - Whirlpool CA15WYR0 Use And Care Manual

Whirlpool room air conditioner use & care guide
Table of Contents

Advertisement

Window Installation
Window opening measurements:
27" (68.6 cm) minimum to 40" (101.6 cm) maximum opening
width.
19" (48.3 cm) minimum opening height.
A. 27" (68.6 cm) minimum, 40" (101.6 cm) maximum
B. 19" (48.3 cm) minimum
Through-the-Wall Installation
The wall opening measurements should be:
Height: 18" (45.7 cm) plus twice the thickness of wood used
to build frame.
Width: 26" (66 cm) plus twice the thickness of wood used to
build frame.
Depth: 2" (5 cm) minimum to 8" (20.3 cm) maximum.
A
A. 18" (45.7 cm)
C. Wood thickness
B. 26" (66 cm)
D. 2" (5 cm) minimum to 8" (20.3 cm) maximum
4
A
B
C
B
D
C

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply
cord
Wiring requirements
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or circuit
breaker
Use on single outlet circuit only.
230-volt (207 min. - 253 max.)
"
0-12 amps
(0.6 cm)
15-amp time-delay fuse or circuit
breaker
Use on single outlet circuit only.
Recommended grounding method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's responsibility to have a
properly grounded 3 prong outlet installed by a qualified electrical
installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269

Advertisement

Table of Contents
loading

Table of Contents