Figure 1
I I
a
1 I .
I
3-'PRONG
GROUNDING
WALL RECEPTACLE
POWER-SUPPLY
CORD
ALTERNATE
GROUNDING
METHOD
If changing
and properly
grounding
the wall
receptacle
is impossible
and where
local codes
permit
(consult
your
electrical
inspector),
a
temporary
adapter
may
be plugged
into
the
existing
2-prong wall receptacle to mate with the
3-prong
power supply
cord. See Figure 2. THIS,
HOWEVER,
IS NOT RECOMMENDED.
If this is done, you must connect
the grounded
eyelet
on the
adapter
to the wall
receptacle
cover plate screw and from this same screw, you
must
connect
a separate
copper
ground
wire
(#I4
minimum)
to a grounded
cold water pipe.*
See Figure
2. Do not ground
to a gas supply
pipe. Do not connect
to electrical
supply
until
appliance
is permanently
grounded.
Figure 2
t
GROUND ASSEMBLY
(\,
,(""A;;;?
;;;;NDED
3
WATEi
Pi@
COVER PLATE
".,""..",w3
PLUG
.-.. . .--
GROUND PRONG
RECEPTACLE
POWER SUPPLY CORD
*Cold water pipe must have metal continuity
to
electrical
ground
and not
be interrupted
by
plastic,
rubber
or other
electrically
insulating
connectors
(including
water
meter
or pump)
without
adding
a jumper
wire
at these con-
nections.
.
ELECTRICAL
REQUIREMENTS
For 230 volt
and 230/208
volt
models
with
serial plate amperes up through
12.0
Refer to Chart B for specific wiring
and recep-
tacle information
to be used.
OBSERVE
ALL
LOCAL
GOVERNING
CODES
AND ORDINANCES.
Do not,
under
any circumstances,
remove the
power supply cord ground plug.
ELECTRICAL
GROUND
IS REQUIRED
ON
THIS APPLIANCE.
A three-wire,
single-phase
60 hertz
AC only
electrical
supply is required.
A separate
electrical
supply
is required
on a
separately
fused
circuit.
Do not fuse ground-
neutral.
See Chart B for receptacle voltage requirements,
proper
fuse size, wire
and wiring
connections
which must conform
with rating of the appliance.
Do not use an extension
cord.
Chart-B
PLUG AND
RECEPTACLE
DATA
RECEPTACLE
VOLTAGE
(6Q HERTZ
SERIAL
PLATE
AC IN ALL
AMPERES
INSTANCES)
SMALL
TANDEM
BLADES
RECEPTACLE
MODEL WITH
SERIAL PLATE
OF 230 VOLTS
n
r
l/4"
eGROUN0
BLADE'
J
cil
;;
(207 MIN,253
.
MAX.)
up
lhrou9h
MODEL WITH
12.0
PRONG
SERIAL PLATE
?I
OF 230/209
VOLTS
a
(197.6 MIN.
253 MAX,)
USE TIME-DELAY
FUSE
OR TIME
DELAY CIRCUIT
BREAKER
RATING IN
AMPS
MINIMUM
RECEPTACLE
WIRE SUE
SEE SELOW
TYPE
OF BRANCH
CIRCUIT
Go
@
14 GAUGE
SINGLE
OUTLET
USE COPPER
ONLY
15
WIRE ONLY