Specifications; How It Works; Installation Requirements; Installation - Uni-P Dry Pro 200X Installation, Operation & Service Instructions

Table of Contents

Advertisement

Uni-P Pro 200X Dehumidifier

Specifications

Capacity@80℉/60%RH: 120 Pints Per Day
Airflow @ 0.0" SP: 300CFM
Operating Temp. Range: 33-105°F
Operating Relative Humidity Range: 36%-90%
COP: 2.8 L/kWh
Refrigerant: R410A
Amperage Usage: 7.6 Amps
Power Supply: 115V/60Hz/Single Phase
Outlet Requirement: 15 Amp, 3 Prong, GFCI
Sound Level: 60 dBa
Dimensions LxWxH: 23.75" x 14" x 16"
ETL Listed: Yes

How it works

Unipdry dehumidifiers use an integrated humidistat to monitor the conditioned
space. When the relative humidity goes above the selected setpoint, the
dehumidifier will energize. Air is then drawn across an evaporator coil, which is
cooler than the dew point of air. This means moisture will condense out of the air.
The air is then reheated through the condenser coil and distributed back into the
room.

Installation Requirements

The area where the dehumidifier is located should be sealed with a vapor
barrier.
If the unit is installed in a crawl space, all vents should be sealed.
For proper ventilation, neither the inlet or discharge should be positioned
against a wall. The inlet needs a minimum of 12" clearance and the discharge
requires a minimum of 36" clearance.
For the best air diffusion, install the unit so that a side panel faces the wall.
Unipdry dehumidifiers are only intended for operation when the unit
is upright and level with the feet on the ground (unless using a Unipdry
Hanging Kit).
Tel: 888-990-7469
Installation, Operation & Service Instructions
2
Uni-P Pro 200X Dehumidifier

Installation

1. Place dehumidifier on a level surface.
• Do not place unit directly on vapor barrier. For example, use blocks or pavers to create
a level surface.
• If unit has been turned or flipped so that the compressor did not remain upright, place
the unit on a level surface and wait a minimum of 2 hours before proceeding.
2. Set up the drain line
Remove the compression nut and slide it over the end of the hose to be attached to unit.
• Slide the side of hose with compression nut over the insert on the compression fitting
completely.
• Tighten compression nut.
3. Plug dehumidifier into a dedicated 15 amp GFCI protected outlet.

Key Functions

1. Power Key
Use this button to turn the dehumidifier on and off.
• Press once to turn machine on. You will hear two beeps and the light
illuminate green (solid or flashing depending on mode).
• Press the power button a second time and you will hear one beepas the machine
shuts down. Note that there is a 1 minute fan delay.
2. Arrow Buttons
• Use the up and down arrows to set the desired humidity setpoint on the display
screen.
• The setpoint can be any number between 36%-90%. When the indoor humidity is
higher than the setpoint, the unit will operate.
• Keep in mind that the displayed humidity levels are approximate( +/-5%)
3
Installation, Operation & Service Instructions
will
Tel: 888-990-7469

Advertisement

Table of Contents
loading

Table of Contents