Specifications; How It Works; Installation; Key Functions - Uni-P Dry Renegade 1400X Installation, Operation & Service Instructions

Table of Contents

Advertisement

Uni-P Renegade1400X AIR MOVERS

Specifications

Capacity @ 80°F/60%RH: 140 Pints Per Day
Capacity @ 73°F/60%RH: 100 PPD
Airflow @ 0.0" SP: 400CFM
Operating Temp. Range: 35.6-105°F
Operating Relative Humidity Range: 36%-90%
COP: 2.75 L/kWh
Refrigerant: R410A
Amperage Usage: 8.3 Amps
Power Supply: 115V/60Hz/Single Phase
Outlet Requirement: 15 Amp
Sound Level: 60 dBa
Dimensions LxWxH: 23.6" x 22" x 37.2" (600 x 560 x 947 mm)
ETL Listed: Yes

How It Works

Uni-P Dry dehumidifiers use an integrated humidistat to monitor theconditioned space. When
the relative humidity goes above the selected setpoint, the dehumidifier will energize. Air is
then drawn across an evaporator coil, which is cooler than the dew point of air. This means
moisture will condense out of the air. The air is then reheated through the condenser coil and
distributed back into the room.

Installation

1. Place dehumidifier on a level surface.
• Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a
level surface.
• If unit has been turned or flipped so that the compressor did not remain upright, place the
unit on a level surface and wait a minimum of 2 hours before proceeding.
2. Set up the drain line
• Locate the dehumidifier near a suitable drain (6' drain hoseincluded). Allow for proper
drainage and routing of needed drain pipes.
• Connect the drain pipe to the quick connector of the dehumidifier before placing the drain
pipe into the sewer.
• The dehumidifier is equipped with a built-in drainage pump to support the drainage height
of 18 '.
3. Plug dehumidifier into grounded 15 amp circuit.
Tel: 888-994-0895
Installation, Operation & Service Instructions
3
Uni-P Renegade1400X AIR MOVERS

Key Functions

1. Power Key
Use this button to turn the dehumidifier on and off.
Press once to turn machine on. You will hear two beeps and
illuminate green (solid or flashing depending on mode).
• Press the power button a second time and you will hear one beep as the machine shuts
down. Note that there is a 1 minute fan delay.
2. Arrow Buttons
·Use the up and down arrow buttons to set the desired humidity setpoint on the display
screen.
·The setpoint can be any number between 36%-90%. When the indoor humidity is higher
than the setpoint, the unit will operate.
• Keep in mind that the displayed humidity levels are approximate ( +/-5%)
3. Continuous Mode
To set the unit to run continuously regardless of humidity, simply use the down
arrow key to set the humidity below 36%.
The continuous light will illuminate green and the display will show "CO".
• To switch back to normal humidistat operation, use the arrow keys to
move the setpoint above 36%.
4. Manual Drain Button
• If you need to store or move your dehumidifier, press the "Drain" button to remove water
from the integral pump's reservoir.
5. Pump Trouble Warning
• If the pump reservoir level gets too high, the water sensor will activate to prevent
overflow.
•When this occurs, the compressor will stop automatically, and the display will show "E4".
After a 1 minute delay, the fan motor will turn off and the dehumidifier will not operate until
the problem has been resolved.
•Check to verify that the pump is functioning, then unplug the unit for two minutes to reset
the error code.
4
Installation, Operation & Service Instructions
the
light will
Tel: 888-994-0895

Advertisement

Table of Contents
loading

Table of Contents